1. ZheJiang DaMing Refrigeration Technology Co., Ltd.Profyl
- Bedriuwstype: Wy binne fabrikant / fabryk / plant
- Haadprodukten: compressor, compressor unit.(reciprocating compressor, scroll compressor, screw compressor)
- Oantal wurknimmers: 300+
- Jier fan oprjochting: 1990s
- Sertifikaasje fan behearsysteem: ISO 9001
- Lokaasje: ZheJiang, Sina (Fastlân)
2. Basis ynformaasje
- Searjes: 4VD-15.2-4VG-30.2 Taljochting fan model oantsjutting
- Compressor Body Material: Izer 4/6 ———————Silinders
- Applikaasje: Refrigeration S ———————-Model
- Koelgas: R22, R404A, R134A, R507A 15 ————————Hynstekrêft
- Ynfierspanning: 3Ф 380V-420V/50HZ; 440V-480V/60HZ 1 ————————Series Code
- Oarsprong: Zhejiang, Sina D/G———————D foar lege temperatuer; G foar mid- en hege temperatuer
- Spesifikaasje: CE, CCC, ISO9001
3. Applikaasjegrinzen (sûggastemperatuer 20°C)
R404A en R507A
R407C
R22
Oan —— Verdampingstemperatuer (°C)
Toh —- Suggastemperatuer (°C)
Toh —- Suction super waarmte (K)
Tc ——-Kondensaasjetemperatuer (°C)
Ekstra koeling
Oanfoljende koeling & beheinde suction gas temperatuer
Oanfoljend koelsysteem foar koeling en floeistofynjeksje
4.Product Details
4.1 Key Spesifikaasjes / Spesjale eigenskippen -Technical Data Sheet
Model | Nominale PowerHP/KW | Ferpleatsing m³/h 50Hz | Oantal silinders × Diameter × Stoke | Exhaust & Suction Valve mm / IN | Oaljevolume (L) | Power V/φ/Hz | Elektryske parameter | Crankcase Heater (220V)W | Oalje SupplyMethod | Gewicht (ynklusyf oalje) kg | ||
DL-útlaatklep | SLSuction Valve | Max Operating Current (A) | Starting/ Locked Current (A) | |||||||||
4VD-15.2 | 15/10.5 | 73.7 | 4×φ70×55 | φ28 | φ42 | 4 | 380-420YY/3/50 440-480YY/3/60 | 31 | 81/132 | 140 | Forced-lubrication | 183 |
4VG-25.2 | 25/18.5 | 73.7 | 4×φ70×55 | φ28 | φ54 | 4.5 | 45 | 116/193 | 140 | 203 | ||
4VD-20.2 | 20/15 | 84.6 | 4×φ75×55 | φ28 | φ54 | 4.5 | 37 | 97/158 | 140 | 192 | ||
4VG-30.2 | 30/22 | 84.6 | 4×φ75×55 | φ28 | φ54 | 4.5 | 53 | 135/220 | 140 | 206 |
4.2 Refrigerating Performance - Cooling Kapasiteit mei R22
Model | Kondensaasjetemperatuer ℃ | Koelkapasiteit Qo(W) Stromferbrûk Pe(kW) | |||||||||||||
Ferdampingstemperatuer ℃ | |||||||||||||||
12.5 | 10 | 7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | -35 | -40 | |||
4VD-15.2 | 30 | Qo | 52300 | 42700 | 34450 | 27350 | 21300 | 16400 | 12000 | 8310 | |||||
Pe | 12.73 | 11.93 | 11.01 | 9.98 | 8.82 | 8.25 | 7.13 | 5.98 | |||||||
40 | Qo | 46850 | 38100 | 30500 | 24050 | 18500 | 13840 | 9800 | 6440 | ||||||
Pe | 14.91 | 13.81 | 12.56 | 11.19 | 9.76 | 8.67 | 7.30 | 5,90 | |||||||
50 | Qo | 41700 | 33700 | 26800 | 20900 | 15800 | 11500 | 7920 | 4970 | ||||||
Pe | 17.11 | 15.67 | 14.13 | 12.47 | 10.85 | 9.21 | 7.53 | 5.79 | |||||||
4VG-25.2 | 30 | Qo | 99300 | 91200 | 83600 | 76500 | 63700 | 52600 | 42950 | 34650 | 27500 | 21400 | 16260 | ||
Pe | 13.89 | 13.74 | 13.56 | 13.34 | 12.84 | 12.22 | 11.48 | 10.63 | 9.67 | 8.59 | 7.41 | ||||
40 | Qo | 89700 | 82300 | 75400 | 68900 | 57300 | 47150 | 38350 | 30800 | 24250 | 18670 | 13940 | |||
Pe | 16.75 | 16.47 | 16.16 | 15.82 | 15.05 | 14.17 | 13.18 | 12.07 | 10.85 | 9.52 | 8.08 | ||||
50 | Qo | 80500 | 73800 | 67600 | 61700 | 51100 | 41950 | 33950 | 27050 | 21100 | 16030 | ||||
Pe | 19.56 | 19.16 | 18.74 | 18.27 | 17.25 | 16.10 | 14.83 | 13.44 | 11.94 | 10.33 | |||||
4VD-20.2 | 30 | Qo | 60000 | 48950 | 39500 | 31400 | 24500 | 18940 | 13920 | 9670 | |||||
Pe | 14.64 | 13.67 | 12.63 | 11.51 | 10.29 | 9.65 | 8.40 | 7.10 | |||||||
40 | Qo | 53700 | 43700 | 35100 | 27750 | 21500 | 16080 | 11430 | 7530 | ||||||
Pe | 17.39 | 16.04 | 14.60 | 13.07 | 11.42 | 10.35 | 8.75 | 7.14 | |||||||
50 | Qo | 47800 | 38750 | 30950 | 24200 | 18350 | 13390 | 9230 | 5790 | ||||||
Pe | 20.10 | 18.40 | 16.65 | 14.89 | 13.14 | 11.23 | 9.19 | 7.06 | |||||||
4VG-30.2 | 30 | Qo | 114200 | 104800 | 96000 | 87800 | 73100 | 60400 | 49300 | 39800 | 31650 | 24700 | 18840 | ||
Pe | 16.42 | 16.23 | 16.01 | 15.74 | 15.11 | 14.33 | 13.44 | 12.45 | 11.36 | 10.21 | 9.00 | ||||
40 | Qo | 103000 | 94500 | 86500 | 79100 | 65700 | 54000 | 44000 | 35350 | 27950 | 21650 | 16330 | |||
Pe | 19.78 | 19.46 | 19.09 | 18.68 | 17.74 | 16.67 | 15.49 | 14.20 | 12.83 | 11.40 | 9.92 | ||||
50 | Qo | 92300 | 84600 | 77400 | 70700 | 58600 | 48100 | 39000 | 31200 | 24500 | 18810 | ||||
Pe | 23.40 | 22.90 | 22.30 | 21.70 | 20.40 | 19.04 | 17.57 | 16.05 | 11.49 | 12.91 | |||||
Basearre op 20 ℃ suction gas temperatuer, 50Hz, sûnder floeibere subcooling. | |||||||||||||||
VARICOOL systeem, ekstra koeling, posysje fan suction fentyl feroare. | |||||||||||||||
Oanfoljende koeling of beheind suction gas temperatuer. | |||||||||||||||
Oanfoljende koeling en CIC systeem. |
Refrigerating Performance - Cooling Kapasiteit mei R404A, R507A
Model | Kondensaasjetemperatuer ℃ | Koelkapasiteit Qo(W) Stromferbrûk Pe(kW) | ||||||||||||
Ferdampingstemperatuer ℃ | ||||||||||||||
7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | -35 | -40 | -45 | |||
4VD-15.2 | 30 | Qo | 58500 | 48400 | 39700 | 32200 | 25750 | 20250 | 15560 | 11630 | 8350 | |||
Pe | 15.78 | 14.84 | 13.79 | 12.63 | 11.40 | 10.10 | 8.77 | 7.43 | 6.10 | |||||
40 | Qo | 49850 | 41150 | 33600 | 27100 | 21500 | 16730 | 12660 | 9240 | 6380 | ||||
Pe | 18.16 | 16.80 | 15.34 | 13.82 | 12.25 | 10.65 | 9.05 | 7.47 | 5.93 | |||||
50 | Qo | 33950 | 27600 | 22050 | 17330 | 13270 | 9820 | 6920 | ||||||
Pe | 18.50 | 16.67 | 14.80 | 12.91 | 11.03 | 9.17 | 7.37 | |||||||
4VG-25.2 | 30 | Qo | 90700 | 83200 | 69700 | 57900 | 47750 | 38950 | 31350 | 24800 | 19210 | 14460 | 10460 | |
Pe | 16.14 | 16.07 | 15.72 | 15.14 | 14.36 | 13.41 | 12.32 | 11.11 | 9.81 | 8.46 | 7.08 | |||
40 | Qo | 77400 | 71000 | 59500 | 49400 | 40650 | 33000 | 26450 | 20800 | 15930 | 11800 | 8320 | ||
Pe | 19.56 | 19.22 | 18.37 | 17.32 | 16.11 | 14.76 | 13.31 | 11.78 | 10.20 | 8.60 | 7.00 | |||
50 | Qo | 64500 | 59100 | 49500 | 41000 | 33600 | 27200 | 21600 | 16830 | 12740 | 9260 | 6340 | ||
Pe | 22.78 | 22.18 | 20.84 | 19.33 | 17.71 | 15.98 | 14.18 | 12.34 | 10.49 | 8.65 | 6.86 | |||
4VD-20.2 | 30 | Qo | 67100 | 55500 | 45400 | 36750 | 29350 | 23000 | 17600 | 13060 | 9260 | |||
Pe | 18.22 | 17.12 | 15.89 | 14.55 | 13.12 | 11.62 | 10.08 | 8.53 | 6.97 | |||||
40 | Qo | 57200 | 47300 | 38700 | 31200 | 24800 | 19250 | 14540 | 10540 | 7160 | ||||
Pe | 20.94 | 19.36 | 17.68 | 15.93 | 14.13 | 12.30 | 10.47 | 8.65 | 6.89 | |||||
50 | Qo | 38750 | 31650 | 25450 | 20100 | 15480 | 11510 | 8120 | ||||||
Pe | 21.25 | 19.15 | 17.02 | 14.87 | 12.73 | 10.63 | 8.60 | |||||||
4VG-30.2 | 30 | Qo | 103800 | 95300 | 79900 | 66500 | 54900 | 44900 | 36250 | 28800 | 22450 | 17040 | 12480 | |
Pe | 19.21 | 19.07 | 18.57 | 17.81 | 16.84 | 15.70 | 14.41 | 13.02 | 11.57 | 10.09 | 8.61 | |||
40 | Qo | 89100 | 81800 | 68600 | 57000 | 47000 | 38250 | 30700 | 24200 | 18610 | 13860 | 9850 | ||
Pe | 23.37 | 22.88 | 21.73 | 20.38 | 18.88 | 17.26 | 15.56 | 13.81 | 12.06 | 10.33 | 8.68 | |||
50 | Qo | 74300 | 68200 | 57100 | 47400 | 38900 | 31500 | 25100 | 19580 | 14840 | 10810 | 7410 | ||
Pe | 27.01 | 26.20 | 24.46 | 22.58 | 20.60 | 18.56 | 16.50 | 14.45 | 12.45 | 10.54 | 8.76 | |||
Basearre op 20 ℃ suction gas temperatuer, 50Hz, sûnder floeibere subcooling. | ||||||||||||||
Oanfoljende koeling of beheind suction gas temperatuer. | ||||||||||||||
Oanfoljende koeling en CIC systeem. |
Refrigerating Performance - Cooling Kapasiteit mei r134a
Model | Kondensaasjetemperatuer ℃ | Koelkapasiteit Qo(W) Stromferbrûk Pe(kW) | |||||||||||
Ferdampingstemperatuer ℃ | |||||||||||||
12.5 | 10 | 7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | |||
4VD-15.2 | 30 | Qo | 69100 | 62800 | 57000 | 51600 | 49150 | 33700 | 26700 | 20850 | 15920 | 11840 | 8500 |
Pe | 10.40 | 10.07 | 9.74 | 9.41 | 8.74 | 8.07 | 7.38 | 6.67 | 5.95 | 5.20 | 4.42 | ||
40 | Qo | 61300 | 55700 | 50400 | 45600 | 37000 | 29600 | 23350 | 18100 | 13700 | 10060 | 7080 | |
Pe | 12.46 | 11.93 | 11.43 | 10.93 | 9.97 | 9.04 | 8.13 | 7.23 | 6.32 | 5.39 | 4.44 | ||
50 | Qo | 54100 | 49050 | 44400 | 40100 | 32400 | 25800 | 20250 | 15570 | 11660 | 8430 | 5800 | |
Pe | 14.24 | 13.54 | 12.87 | 12.22 | 10.99 | 9.81 | 8.69 | 7.59 | 6.51 | 5.43 | 4.34 | ||
4VG-25.2 | 50 | Qo | 54100 | 49050 | 44400 | 40100 | 32400 | 25800 | 20250 | 15570 | 11660 | ||
Pe | 13.77 | 13.13 | 12.52 | 11.92 | 10.78 | 9.68 | 8.62 | 7.58 | 6.55 | ||||
60 | Qo | 47100 | 42700 | 38600 | 34800 | 28000 | 22200 | 17320 | 13190 | 9760 | |||
Pe | 15.04 | 14.27 | 13.53 | 12.81 | 11.44 | 10.13 | 8.89 | 7.69 | 6.53 | ||||
70 | Qo | 40250 | 36450 | 32900 | 29600 | 23750 | 18740 | 14500 | 10940 | 7980 | |||
Pe | 16.09 | 15.21 | 14.36 | 13.53 | 11.96 | 10.48 | 9.07 | 7.74 | 6.45 | ||||
4VD-20.2 | 30 | Qo | 78500 | 71400 | 64800 | 58600 | 47700 | 38350 | 30450 | 23800 | 18190 | 13560 | 9770 |
Pe | 12.45 | 12.15 | 11.83 | 11.50 | 10.78 | 10.00 | 9.16 | 8.26 | 7.31 | 6.32 | 5.28 | ||
40 | Qo | 69700 | 63300 | 57400 | 51900 | 42100 | 33750 | 26650 | 20700 | 15700 | 11570 | 8190 | |
Pe | 14.65 | 14.14 | 13.62 | 13.09 | 12.03 | 10.95 | 9.85 | 8.73 | 7.59 | 6.44 | 5.28 | ||
50 | Qo | 61500 | 55800 | 50500 | 45650 | 36950 | 29500 | 23200 | 17870 | 13430 | 9760 | 6770 | |
Pe | 16.67 | 15.93 | 15.20 | 14.48 | 13.06 | 11.67 | 10.31 | 8.97 | 7.66 | 6.37 | 5.10 | ||
4VG-30.2 | 50 | Qo | 61500 | 55800 | 50500 | 45650 | 36950 | 29500 | 23200 | 17870 | 13430 | ||
Pe | 16.09 | 15.42 | 14.76 | 14.10 | 12.79 | 11.50 | 10.22 | 8.94 | 7.67 | ||||
60 | Qo | 53700 | 48650 | 44000 | 39700 | 32000 | 25450 | 19890 | 15210 | 11300 | |||
Pe | 17.65 | 16.80 | 15.96 | 15.14 | 13.54 | 11.99 | 10.49 | 9.03 | 7.60 | ||||
70 | Qo | 45900 | 41600 | 37600 | 33850 | 27200 | 21550 | 16720 | 12680 | 9320 | |||
Pe | 19.22 | 18.16 | 17.14 | 16.15 | 14.25 | 12.46 | 10.75 | 9.12 | 7.55 | ||||
Suction gas temperatuer 20 ℃, 50Hz, sûnder floeibere subcooling. | |||||||||||||
Oanfoljende koeling of beheind suction gas temperatuer. |
4.3 Processing Features
De kompressors fan Daming passe by ferskate wurkkondysjes en koelmiddelen, en kinne jo easken foar it koelsysteem maksimaal foldwaan.
Ûntwikkele technology, kompakte diminsje, Lyts folume en romte.
Hege presyzje ferwurkjen om te garandearjen dat de kompressor befêstigje mei de standert, CNC-ferwurkingssintrum, konsintrisiteit troch spesifike ferwurkingstechnology, minimale deade romte.
Stabile operaasje, lytse trilling en leech lûd, poerbêste stabiliteit.
Koelmiddel lykas R22 en R404 wurde oannommen om it miljeu te beskermjen, foar tapassing fan mids en lege temperatueren.
Elektryske motor beskerme apparaat, PTC sensor.
Slijtbestindige bestjoerder gear, Verchroomde zuigerringen en aluminium zuigers, ferhurde crank-as, Lege friksje lagerset.
Effisjint fentylplaatûntwerp, hege koelkapasiteit en leech enerzjyferbrûk, effisjinte kompresjerate, fentylreed makke fan ymporteare slagbestindich maitiidstaal.
Algemiene spare dielen, handich foar ûnderhâld.
4.4 Cross Reference (Applikaasjegrinzen)
Cross Reference | ||||
Ûnderdiel Beskriuwing | Daming Model | Copeland Model | Bitzer Model | Ferpleatsing (KW) |
2 silinder | BFS31 | C-0300 | 12.2 | |
BFS41 | C-0400 | 14.7 | ||
BFS51 | C-0500 | 18.4 | ||
BFS81 | C-0800 | 26.6 | ||
BFS101 | C-1000 | 36 | ||
3 silinder | BFS151 | C-1500 | 54 | |
4 silinder | 4S151D | 4SLW-1500 | 73.6 | |
4S251G | 4SHH-2500 | 73.6 | ||
4S201D | 4STW-2000 | 84,5 | ||
4S301G | 4STH-3000 | 84,5 | ||
6 silinder | 6S251D | 6SLW-2500 | 110,5 | |
6S351G | 6SHH-3500 | 110,5 | ||
6S321D | 6STW-3200 | 126.8 | ||
6S401G | 6SJH-4000 | 126.8 | ||
6S401D | 6SUW-4000 | 151,6 | ||
6S501G | 6SKH-5000 | 151,6 | ||
Lytse grutte 2 silinder | 2YD-2.2 | 2DC-2.2 | 13.5 | |
2YG-3.2 | 2DC-3.2 | 13.5 | ||
2YD-3.2 | 2CC-3.2 | 16.2 | ||
2YG-4.2 | 2CC-4.2 | 16.2 | ||
Lytse grutte 4 sill (hexagon foarm) | 4YD-3.2 | 4FC-3.2 | 18.1 | |
4YG-5.2 | 4FC-5.2 | 18.1 | ||
4YD-4.2 | 4EC-4.2 | 22.7 | ||
4YG-6.2 | 4EC-6.2 | 22.7 | ||
4YD-5.2 | 4DC-5.2 | 26.84 | ||
4YG-7.2 | 4DC-7.2 | 26.84 | ||
4YD-6.2 | 4CC-6.2 | 32.48 | ||
4YG-9.2 | 4CC-9.2 | 32.48 | ||
Middelgrutte 4 silinder (hexagon foarm) | 4YD-8.2 | 4TCS-8.2 | 41.33 | |
4YG-12.2 | 4TCS-12.2 | 41.33 | ||
4YD-10.2 | 4PCS-10.2 | 48,5 | ||
4YG-15.2 | 4PCS-15.2 | 48,5 | ||
4YD-12.2 | 4NCS-12.2 | 56.25 | ||
4YG-20.2 | 4NCS-20.2 | 56.25 | ||
Grutte 4 silinders | 4VD-15.2 | 4H-15,2 | 73.6 | |
4VG-25.2 | 4H-25.2 | 73.6 | ||
4VD-20.2 | 4G-20.2 | 84,5 | ||
4VG-30.2 | 4G-30.2 | 84,5 | ||
Grutte 6 silinders | 6WD-25.2 | 6H-25.2 | 110,5 | |
6WG-35.2 | 6H-35,2 | 110,5 | ||
6WD-30.2 | 6G-30.2 | 126.8 | ||
6WG-40.2 | 6G-40.2 | 126.8 | ||
6WD-40.2 | 6F-40.2 | 151,6 | ||
6WG-50.2 | 6F-50.2 | 151,6 | ||
Dûbele poadium | 6WDS-20.2 | S6H-20.2 | 110,5 | |
6WDS-25.2 | S6G-25.2 | 126.8 | ||
6WDS-30.2 | S6F-30.2 | 151,6 |
4.5 Compressor Dimensional tekening
4.6 Ferpakking en ferstjoering
- FOB-poarte: Ningbo Lead Time: 15- 30 dagen
- Packaging Grutte: 49 * 44 * 15 sm Netto gewicht: 62 kg +
- Ienheden per eksportkarton: 1 bruto gewicht: 70 kg +
- Ofmjittings per ienheid: 193 × 94 × 87 sintimeter
- Gewicht per ienheid: 117 kilogram
- Eksportkartongewicht: 117 kilogram
- Eksportearje Carton Ofmjittings L / W / H: 193 × 94 × 87 sintimeter
5. Betelling & Levering
- Betelmetoade: Advance TT, T/T, L/C.
- Leveringsdetails: binnen 30-50 dagen nei ûntfangst fan jo folsleine betelling.
3.7 Primêr konkurrinsjefoardiel
- Lytse oarders akseptearre Brand-namme Parts Lân fan oarsprong
- Distributorships oanbean Electronic Link Erfarne personiel
- Form In Grien Product Kosten-effektyf
- Ynternasjonale Approvals Militêre Spesifikaasjes Standert Packaging
- Goede priis Product Features Product Performance
- Prompt Delivery Quality Approvals Reputaasje
- Soargje foar goede tsjinst Sample Beskikber Oanpast
- Wy hawwe mear as 30 jier beropsûnderfining as fabrikant fan semi-hermetyske kompressor, scrollkompressor, skroefkompressor, kondensearjende ienheid.
- Wy meitsje de kompressor neffens jo gebrûk
- Wy hawwe sterk ûndersyk en ûntwikkeljen team te foldwaan oan jo eask.
- D'r binne in protte leveransiers fan grûnstoffen om ús fabryk, ús fabryk yn Zhejiang
- Wy leverje hege kwaliteit compressor foar in protte wrâldbedriuwen
- Us fabryk krige ISO 9001 en tapasse CE-sertifikaat, wat wichtich is dat wy in fabryk hawwe dy't gruttere workshop oer 20000sq meter hawwe.
- Lytse proefopdrachten kinne wurde akseptearre, sample is beskikber.
- Us priis is ridlik en hâldt topkwaliteit foar elke kliïnt.