2. Basic Information
- Series: 6D-25.2-6DS-30.2 Name Method
- Compressor Body Material: Iron
- Usage: refrigeration
- Refrigeration gas: R22, R404A,R134A,R507A
- Input Voltage: 3Ф 380V-420V/50HZ;440V-480V/60HZ
- Origin: Zhejiang, China
- Specification: CE, CCC,ISO900
3.Product Details
3.1 Key Specifications/Special Features -Technical Data Sheet
Technical parameters | ||||||||||||
Model | NominalPowerHP/KW | Displacement m³/h | Number ofcylinders×Diameter×Stoke
(mm) |
Aspirator,Exhaust Valve mm/min | InjectionVolume (L) | PowerV/φ/Hz | Electrical Parameter | Crankcase Heater (220V)W | Oil SupplyMethod | Weight(including freezing oil) ㎏ | ||
High Pressure | DL | SL | Max Operating Current(A) | Starting/ Locked Current(A) | ||||||||
RFC6D-25.2 | 25/18.5 | 110.5 | 6×φ70×55 | Φ35 (1+3/8″) | Φ54 (2+1/8″) | 4.75 | 380/420 YY/3/50 440-480 YY/3/60 | 45 | 116/193 | 140 | Forced-lubrication | 224 |
RFC6G-35.2 | 35/25.5 | 110.5 | 6×φ70×55 | Φ35 (1+3/8″) | Φ54 (2+1/8″) | 4.75 | 61 | 147/262 | 140 | 235 | ||
RFC6D-30.2 | 30/22 | 126.8 | 6×φ75×55 | Φ35 (1+3/8″) | Φ54 (2+1/8″) | 4.75 | 53 | 135/220 | 140 | 228 | ||
RFC6G-40.2 | 40/30 | 126.8 | 6×φ75×55 | Φ35 (1+3/8″) | Φ54 (2+1/8″) | 4.75 | 78 | 180/323 | 140 | 238 | ||
RFC6D-40.2 | 40/30 | 151.6 | 6×φ82×55 | Φ42 (1+5/8″) | Φ54 (2+1/8″) | 4.75 | 78 | 180/323 | 140 | 239 | ||
RFC6G-50.2 | 50/37 | 151.6 | 6×φ82×55 | Φ42 (1+5/8″) | Φ54 (2+1/8″) | 4.75 | 92 | 226/404 | 140 | 241 | ||
RFC6DS-20.2 | 20/15 | 110.5 | 6×φ70/70×55 | Φ35 (1+3/8″) | Φ42 (1+5/8″) | 4.75 | 37 | 97/158 | 140 | 220 | ||
RFC6DS-25.2 | 25/18.5 | 126.8 | 6×φ75/75×55 | Φ35 (1+3/8″) | Φ42 (1+5/8″) | 4.75 | 45 | 116/193 | 140 | 233 | ||
RFC6DS-30.2 | 30/22 | 151.6 | 6×φ82/82×55 | Φ35 (1+3/8″) | Φ42 (1+5/8″) | 4.75 | 53 | 135/220 | 140 | 234 |
3.2 Refrigerating Performance – Cooling Capacity
Refrigerating Performance - Cooling Capacity with R404A,R507A
Model | Condensing
Temperature℃ |
Refrigerating Capacity Qo(W) Power Consumption Pe(kW) | ||||||||||||
Evaporating Temperature ℃ | ||||||||||||||
7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | -35 | -40 | -45 | |||
RFC4D-3.2 | 30 | Qo | 13720 | 11330 | 9260 | 7470 | 5940 | 4630 | 3510 | 2580 | 1800 | |||
Pe | 3.85 | 3.66 | 3.44 | 3.18 | 2.90 | 2.58 | 2.24 | 1.88 | 1.50 | |||||
40 | Qo | 11560 | 9520 | 7740 | 6200 | 4880 | 3750 | 2790 | 1980 | 1310 | ||||
Pe | 4.42 | 4.10 | 3.76 | 3.40 | 3.03 | 2.63 | 2.23 | 1.82 | 1.40 | |||||
50 | Qo | 9450 | 7740 | 6260 | 4970 | 3860 | 2910 | 2110 | 1430 | |||||
Pe | 4.91 | 4.48 | 4.04 | 3.59 | 3.13 | 2.67 | 2.22 | 1.77 | ||||||
RFC4G-5.2 | 30 | Qo | 21550 | 19790 | 16590 | 13810 | 11400 | 9320 | 7520 | 5970 | 4650 | 3530 | 2580 | |
Pe | 3.78 | 3.79 | 3.76 | 3.67 | 3.52 | 3.32 | 3.07 | 2.79 | 2.48 | 2.15 | 1.81 | |||
40 | Qo | 18240 | 16740 | 14020 | 11650 | 9580 | 7790 | 6240 | 4900 | 3760 | 2790 | 1970 | ||
Pe | 4.65 | 4.60 | 4.46 | 4.25 | 3.99 | 3.69 | 3.35 | 2.98 | 2.59 | 2.18 | 1.76 | |||
50 | Qo | 14970 | 13730 | 11470 | 9500 | 7780 | 6280 | 4980 | 3860 | 2900 | 2090 | 1410 | ||
Pe | 5.44 | 5.33 | 5.07 | 4.75 | 4.39 | 3.98 | 3.55 | 3.10 | 2.62 | 2.14 | 1.65 | |||
RFC4D-4.2 | 30 | Qo | 17330 | 14290 | 11660 | 9400 | 7450 | 5800 | 4390 | 3210 | 2220 | |||
Pe | 4.61 | 4.39 | 4.12 | 3.81 | 3.45 | 3.06 | 2.65 | 2.22 | 1.78 | |||||
40 | Qo | 14440 | 11870 | 9650 | 7720 | 6070 | 4650 | 3450 | 2440 | 1590 | ||||
Pe | 5.28 | 4.93 | 4.53 | 4.10 | 3.64 | 3.15 | 2.65 | 2.14 | 1.63 | |||||
50 | Qo | 11650 | 9550 | 7720 | 6130 | 4760 | 3590 | 2590 | 1750 | |||||
Pe | 5.86 | 5.39 | 4.87 | 4.33 | 3.77 | 4.19 | 2.60 | 2.02 | ||||||
RFC4G-6.2 | 30 | Qo | 27500 | 25200 | 21100 | 17580 | 14500 | 11830 | 9530 | 7550 | 5860 | 4420 | 3210 | |
Pe | 4.73 | 4.75 | 4.73 | 4.62 | 4.43 | 4.17 | 3.85 | 3.48 | 3.08 | 2.65 | 2.21 | |||
40 | Qo | 23150 | 21250 | 17780 | 14750 | 12120 | 9840 | 7860 | 6160 | 4700 | 3470 | 2420 | ||
Pe | 5.87 | 5.81 | 5.62 | 5.35 | 5.01 | 4.61 | 4.17 | 3.68 | 3.17 | 2.65 | 2.12 | |||
50 | Qo | 18930 | 17360 | 14490 | 11980 | 9790 | 7890 | 6240 | 4820 | 3600 | 2570 | 1710 | ||
Pe | 6.86 | 6.72 | 6.37 | 5.95 | 5.47 | 4.95 | 4.38 | 3.79 | 3.19 | 2.58 | 1.97 | |||
RFC4D-5.2 | 30 | Qo | 21100 | 17420 | 14220 | 11470 | 9100 | 7080 | 5370 | 3930 | 2730 | |||
Pe | 5.52 | 5.29 | 4.99 | 4.62 | 4.18 | 3.70 | 3.19 | 2.66 | 2.11 | |||||
40 | Qo | 17650 | 14520 | 11810 | 9460 | 7440 | 5720 | 4250 | 3010 | 1980 | ||||
Pe | 6.34 | 5.95 | 5.50 | 4.99 | 4.43 | 3.83 | 3.22 | 2.60 | 1.98 | |||||
50 | Qo | 14300 | 11730 | 9490 | 7550 | 5880 | 4440 | 3220 | 2190 | |||||
Pe | 7.07 | 6.53 | 5.93 | 5.29 | 4.62 | 3.92 | 3.22 | 2.52 | ||||||
RFC4G-7.2 | 30 | Qo | 32600 | 29900 | 25000 | 20800 | 17120 | 13950 | 11210 | 8860 | 6860 | 5160 | 3720 | |
Pe | 5.49 | 5.52 | 5.51 | 5.39 | 5.18 | 4.88 | 4.52 | 4.10 | 3.63 | 3.12 | 2.59 | |||
40 | Qo | 27500 | 25200 | 21100 | 17490 | 14350 | 11630 | 9270 | 7250 | 5510 | 4040 | 2800 | ||
Pe | 6.81 | 6.75 | 6.55 | 6.26 | 5.88 | 5.43 | 4.91 | 4.35 | 3.74 | 3.11 | 2.47 | |||
50 | Qo | 22500 | 20600 | 17210 | 14230 | 11620 | 9350 | 7380 | 5690 | 4240 | 3010 | 1980 | ||
Pe | 7.98 | 7.83 | 7.46 | 7.00 | 6.46 | 5.86 | 5.20 | 4.50 | 3.78 | 3.03 | 2.28 | |||
RFC4D-6.2 | 30 | Qo | 24950 | 20650 | 16900 | 13670 | 10900 | 8540 | 6530 | 4840 | 3420 | |||
Pe | 6.65 | 6.36 | 5.98 | 5.52 | 5.01 | 4.45 | 3.86 | 3.25 | 2.63 | |||||
40 | Qo | 21100 | 17420 | 14200 | 11420 | 9030 | 6980 | 5240 | 3770 | 2540 | ||||
Pe | 7.64 | 7.17 | 6.63 | 6.03 | 5.37 | 4.67 | 3.94 | 3.20 | 2.47 | |||||
50 | Qo | 17320 | 14220 | 11520 | 9190 | 7180 | 5460 | 4000 | 2770 | |||||
Pe | 8.61 | 7.98 | 7.28 | 6.51 | 5.71 | 4.87 | 4.01 | 3.14 | ||||||
RFC4G-9.2 | 30 | Qo | 38800 | 35600 | 29900 | 24900 | 20600 | 16880 | 13660 | 10890 | 8530 | 6530 | 4840 | |
Pe | 6.85 | 6.87 | 6.82 | 6.64 | 6.36 | 5.98 | 5.53 | 5.01 | 4.45 | 3.86 | 3.25 | |||
40 | Qo | 32850 | 30150 | 25300 | 21100 | 17410 | 14210 | 11440 | 9050 | 7000 | 5250 | 3770 | ||
Pe | 8.35 | 8.27 | 8.01 | 7.64 | 7.18 | 6.63 | 6.02 | 5.36 | 4.66 | 3.94 | 3.20 | |||
50 | Qo | 27050 | 24850 | 20900 | 17380 | 14310 | 11620 | 9280 | 7240 | 5480 | 3960 | 2660 | ||
Pe | 9.80 | 9.62 | 9.16 | 8.61 | 7.98 | 7.28 | 6.52 | 5.71 | 4.87 | 4.01 | 3.14 | |||
RFC4D-8.2 | 30 | Qo | 33050 | 27250 | 22200 | 17890 | 14170 | 10990 | 8300 | 6040 | 4150 | |||
Pe | 8.74 | 8.17 | 7.55 | 6.87 | 6.16 | 5.41 | 4.64 | 3.86 | 3.07 | |||||
40 | Qo | 27750 | 22800 | 18480 | 14760 | 11560 | 8830 | 6520 | 4580 | 2960 | ||||
Pe | 9.86 | 9.05 | 8.20 | 7.34 | 6.46 | 5.57 | 4.66 | 3.74 | 2.81 | |||||
50 | Qo | 18350 | 14790 | 11710 | 9070 | 6800 | 4880 | 3260 | ||||||
Pe | 9.74 | 8.71 | 7.68 | 6.65 | 5.61 | 4.55 | 3.46 | |||||||
RFC4G-12.2 | 30 | Qo | 51500 | 47200 | 39450 | 32750 | 26900 | 21900 | 17550 | 13830 | 10650 | 7960 | 5700 | |
Pe | 8.63 | 8.63 | 8.49 | 8.22 | 7.81 | 7.29 | 6.68 | 6.00 | 5.26 | 4.48 | 3.68 | |||
40 | Qo | 43500 | 39850 | 33300 | 27550 | 22600 | 18260 | 14530 | 11320 | 8590 | 6270 | 4320 | ||
Pe | 10.66 | 10.47 | 9.99 | 9.40 | 8.72 | 7.96 | 7.15 | 6.29 | 5.40 | 4.51 | 3.62 | |||
50 | Qo | 35400 | 32400 | 27050 | 22350 | 18230 | 14650 | 11550 | 8880 | 6590 | 4650 | 3020 | ||
Pe | 12.28 | 11.93 | 11.17 | 10.33 | 9.42 | 8.45 | 7.45 | 6.42 | 5.39 | 4.36 | 3.36 | |||
RFC4D-10.2 | 30 | Qo | 38300 | 31600 | 25750 | 20700 | 16390 | 12690 | 9550 | 6910 | 4690 | |||
Pe | 10.07 | 9.37 | 8.64 | 7.87 | 7.06 | 6.22 | 5.34 | 4.43 | 3.48 | |||||
40 | Qo | 32300 | 26500 | 21500 | 17130 | 13400 | 10220 | 7520 | 5240 | 3350 | ||||
Pe | 11.39 | 10.45 | 9.47 | 8.45 | 7.41 | 6.35 | 5.30 | 4.25 | 3.22 | |||||
50 | Qo | 21500 | 17290 | 13660 | 10550 | 7890 | 5640 | 3760 | ||||||
Pe | 11.26 | 10.04 | 8.80 | 7.53 | 6.28 | 5.05 | 3.88 | |||||||
RFC4G-15.2 | 30 | Qo | 61500 | 56400 | 47100 | 39050 | 32100 | 26000 | 20800 | 16320 | 12490 | 9240 | 6500 | |
Pe | 10.23 | 10.19 | 9.96 | 9.58 | 9.06 | 8.43 | 7.70 | 6.90 | 6.04 | 5.14 | 4.23 | |||
40 | Qo | 52200 | 47850 | 39950 | 33050 | 27050 | 21850 | 17360 | 13490 | 10190 | 7390 | 5020 | ||
Pe | 12.41 | 12.14 | 11.51 | 10.79 | 9.99 | 9.11 | 8.18 | 7.19 | 6.17 | 5.13 | 4.07 | |||
50 | Qo | 42600 | 39000 | 32500 | 26750 | 21800 | 17430 | 13680 | 10460 | 7710 | 5380 | 3420 | ||
Pe | 14.27 | 13.78 | 12.78 | 11.73 | 10.66 | 9.55 | 8.43 | 7.28 | 6.11 | 4.94 | 3.75 | |||
RFC4D-12.2 | 30 | Qo | 44000 | 36250 | 29550 | 23750 | 18810 | 14580 | 11000 | 7980 | 5470 | |||
Pe | 11.88 | 11.15 | 10.30 | 9.35 | 8.35 | 7.30 | 6.23 | 5.19 | 4.18 | |||||
40 | Qo | 37300 | 30600 | 24800 | 19810 | 15510 | 11840 | 8740 | 6120 | 3950 | ||||
Pe | 13.39 | 12.33 | 11.18 | 9.97 | 8.71 | 7.44 | 6.19 | 4.99 | 3.87 | |||||
50 | Qo | 24850 | 20000 | 15820 | 12210 | 9120 | 6510 | 4300 | ||||||
Pe | 13.28 | 11.83 | 10.37 | 8.91 | 7.45 | 6.01 | 4.60 | |||||||
RFC4G-20.2 | 30 | Qo | 71000 | 65100 | 54500 | 45250 | 37200 | 30250 | 24250 | 19070 | 14640 | 10860 | 7660 | |
Pe | 12.24 | 12.20 | 11.94 | 11.47 | 10.82 | 10.04 | 9.14 | 8.16 | 7.12 | 6.07 | 5.02 | |||
40 | Qo | 60500 | 55400 | 46250 | 38200 | 31250 | 25200 | 20000 | 15530 | 11730 | 8510 | 5820 | ||
Pe | 14.78 | 14.49 | 13.79 | 12.91 | 11.91 | 10.80 | 9.62 | 8.40 | 7.16 | 5.95 | 4.78 | |||
50 | Qo | 49900 | 45650 | 37900 | 31100 | 25250 | 20150 | 15760 | 12010 | 8840 | 6180 | 3980 | ||
Pe | 16.78 | 16.28 | 15.18 | 13.95 | 12.63 | 11.24 | 9.81 | 8.38 | 6.97 | 5.63 | 4.37 | |||
RFC4D-15.2 | 30 | Qo | 58500 | 48400 | 39700 | 32200 | 25750 | 20250 | 15560 | 11630 | 8350 | |||
Pe | 15.78 | 14.84 | 13.79 | 12.63 | 11.40 | 10.10 | 8.77 | 7.43 | 6.10 | |||||
40 | Qo | 49850 | 41150 | 33600 | 27100 | 21500 | 16730 | 12660 | 9240 | 6380 | ||||
Pe | 18.16 | 16.80 | 15.34 | 13.82 | 12.25 | 10.65 | 9.05 | 7.47 | 5.93 | |||||
50 | Qo | 33950 | 27600 | 22050 | 17330 | 13270 | 9820 | 6920 | ||||||
Pe | 18.50 | 16.67 | 14.80 | 12.91 | 11.03 | 9.17 | 7.37 | |||||||
RFC4G-25.2 | 30 | Qo | 90700 | 83200 | 69700 | 57900 | 47750 | 38950 | 31350 | 24800 | 19210 | 14460 | 10460 | |
Pe | 16.14 | 16.07 | 15.72 | 15.14 | 14.36 | 13.41 | 12.32 | 11.11 | 9.81 | 8.46 | 7.08 | |||
40 | Qo | 77400 | 71000 | 59500 | 49400 | 40650 | 33000 | 26450 | 20800 | 15930 | 11800 | 8320 | ||
Pe | 19.56 | 19.22 | 18.37 | 17.32 | 16.11 | 14.76 | 13.31 | 11.78 | 10.20 | 8.60 | 7.00 | |||
50 | Qo | 64500 | 59100 | 49500 | 41000 | 33600 | 27200 | 21600 | 16830 | 12740 | 9260 | 6340 | ||
Pe | 22.78 | 22.18 | 20.84 | 19.33 | 17.71 | 15.98 | 14.18 | 12.34 | 10.49 | 8.65 | 6.86 | |||
RFC4D-20.2 | 30 | Qo | 67100 | 55500 | 45400 | 36750 | 29350 | 23000 | 17600 | 13060 | 9260 | |||
Pe | 18.22 | 17.12 | 15.89 | 14.55 | 13.12 | 11.62 | 10.08 | 8.53 | 6.97 | |||||
40 | Qo | 57200 | 47300 | 38700 | 31200 | 24800 | 19250 | 14540 | 10540 | 7160 | ||||
Pe | 20.94 | 19.36 | 17.68 | 15.93 | 14.13 | 12.30 | 10.47 | 8.65 | 6.89 | |||||
50 | Qo | 38750 | 31650 | 25450 | 20100 | 15480 | 11510 | 8120 | ||||||
Pe | 21.25 | 19.15 | 17.02 | 14.87 | 12.73 | 10.63 | 8.60 | |||||||
RFC4G-30.2 | 30 | Qo | 103800 | 95300 | 79900 | 66500 | 54900 | 44900 | 36250 | 28800 | 22450 | 17040 | 12480 | |
Pe | 19.21 | 19.07 | 18.57 | 17.81 | 16.84 | 15.70 | 14.41 | 13.02 | 11.57 | 10.09 | 8.61 | |||
40 | Qo | 89100 | 81800 | 68600 | 57000 | 47000 | 38250 | 30700 | 24200 | 18610 | 13860 | 9850 | ||
Pe | 23.37 | 22.88 | 21.73 | 20.38 | 18.88 | 17.26 | 15.56 | 13.81 | 12.06 | 10.33 | 8.68 | |||
50 | Qo | 74300 | 68200 | 57100 | 47400 | 38900 | 31500 | 25100 | 19580 | 14840 | 10810 | 7410 | ||
Pe | 27.01 | 26.20 | 24.46 | 22.58 | 20.60 | 18.56 | 16.50 | 14.45 | 12.45 | 10.54 | 8.76 | |||
Suction gas temperature 20℃,50Hz,without liquid subcooling. | ||||||||||||||
Additional cooling or limited suction gas temperature. | ||||||||||||||
Additional cooling and CIC system |
Refrigerating Performance - Cooling Capacity with r134a
Model | Condensing
Temperature℃ |
Refrigerating Capacity Qo(W) Power Consumption Pe(kW) | |||||||||||
Evaporating Temperature ℃ | |||||||||||||
12.5 | 10 | 7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | |||
RFC4D-3.2 | 30 | Qo | 15960 | 14520 | 13190 | 11960 | 9760 | 7870 | 6260 | 4900 | 3740 | 2780 | 1970 |
Pe | 2.23 | 2.21 | 2.19 | 2.15 | 2.07 | 1.95 | 1.81 | 1.65 | 1.47 | 1.26 | 1.04 | ||
40 | Qo | 14070 | 12790 | 11610 | 10510 | 8540 | 6860 | 5420 | 4190 | 3160 | 2290 | 1570 | |
Pe | 2.64 | 2.60 | 2.55 | 2.49 | 2.36 | 2.20 | 2.02 | 1.81 | 1.58 | 1.33 | 1.05 | ||
50 | Qo | 12250 | 11130 | 10090 | 9120 | 7390 | 5900 | 4630 | 3540 | 2630 | 1860 | 1220 | |
Pe | 3.04 | 2.96 | 2.88 | 2.80 | 2.61 | 2.41 | 2.19 | 1.94 | 1.66 | 1.36 | 1.02 | ||
RFC4G-5.2 | 50 | Qo | 12200 | 11090 | 10060 | 9090 | 7370 | 5890 | 4620 | 3540 | 2630 | ||
Pe | 3.19 | 3.11 | 3.02 | 2.93 | 2.72 | 2.49 | 2.24 | 1.97 | 1.67 | ||||
60 | Qo | 10490 | 9530 | 8630 | 7800 | 6300 | 5010 | 3900 | 2960 | 2160 | |||
Pe | 3.59 | 3.49 | 3.37 | 3.25 | 3.00 | 2.72 | 2.42 | 2.09 | 1.74 | ||||
70 | Qo | 8800 | 7990 | 7230 | 6530 | 5260 | 4160 | 3210 | 2410 | 1720 | |||
Pe | 3.99 | 3.85 | 3.71 | 3.57 | 3.27 | 2.94 | 2.58 | 2.20 | 1.79 | ||||
RFC4D-4.2 | 30 | Qo | 20700 | 18850 | 17120 | 15510 | 12660 | 10220 | 8160 | 6410 | 4960 | 3750 | 2760 |
Pe | 2.80 | 2.84 | 2.86 | 2.86 | 2.82 | 2.72 | 2.57 | 2.38 | 2.16 | 1.91 | 1.64 | ||
40 | Qo | 18210 | 16550 | 15020 | 13600 | 11060 | 8900 | 7050 | 5490 | 4190 | 3100 | 2200 | |
Pe | 3.48 | 3.47 | 3.44 | 3.39 | 3.25 | 3.06 | 2.83 | 2.55 | 2.25 | 1.92 | 1.58 | ||
50 | Qo | 15740 | 14300 | 12960 | 11720 | 9500 | 7600 | 5970 | 4590 | 3420 | 2450 | 1640 | |
Pe | 4.13 | 4.06 | 3.98 | 3.88 | 3.64 | 3.36 | 3.03 | 2.67 | 2.27 | 1.86 | 1.42 | ||
RFC4G-6.2 | 50 | Qo | 15710 | 14270 | 12940 | 11710 | 9490 | 7600 | 5970 | 4590 | 3430 | ||
Pe | 4.16 | 4.09 | 4.00 | 3.89 | 3.65 | 3.35 | 3.02 | 2.65 | 2.24 | ||||
60 | Qo | 13350 | 12120 | 10970 | 9900 | 7990 | 6340 | 4920 | 3710 | 2690 | |||
Pe | 4.81 | 4.68 | 4.53 | 4.37 | 4.01 | 3.61 | 3.17 | 2.70 | 2.21 | ||||
70 | Qo | 11030 | 10000 | 9030 | 8140 | 6520 | 5110 | 3910 | 2870 | 1990 | |||
Pe | 5.44 | 5.24 | 5.03 | 4.81 | 4.34 | 3.83 | 3.28 | 2.71 | 2.11 | ||||
RFC4D-5.2 | 30 | Qo | 24600 | 22450 | 20400 | 18510 | 15140 | 12250 | 9790 | 7700 | 5930 | 4440 | 3210 |
Pe | 3.61 | 3.55 | 3.49 | 3.42 | 3.26 | 3.08 | 2.86 | 2.62 | 2.35 | 2.05 | 1.72 | ||
40 | Qo | 21700 | 19750 | 17940 | 16270 | 13260 | 10690 | 8480 | 6610 | 5030 | 3700 | 2600 | |
Pe | 4.30 | 4.21 | 4.12 | 4.02 | 3.79 | 3.53 | 3.23 | 2.91 | 2.56 | 2.17 | 1.75 | ||
50 | Qo | 18880 | 17170 | 15580 | 14110 | 11460 | 9190 | 7240 | 5590 | 4190 | 3020 | 2050 | |
Pe | 4.96 | 4.84 | 4.71 | 4.57 | 4.27 | 3.93 | 3.56 | 3.15 | 2.71 | 2.23 | 1.73 | ||
RFC4G-7.2 | 50 | Qo | 18800 | 17100 | 15520 | 14050 | 11430 | 9170 | 7230 | 5580 | 4190 | ||
Pe | 4.99 | 4.86 | 4.73 | 4.58 | 4.27 | 3.92 | 3.54 | 3.13 | 2.69 | ||||
60 | Qo | 16160 | 14680 | 13310 | 12030 | 9750 | 7770 | 6090 | 4650 | 3440 | |||
Pe | 5.62 | 5.46 | 5.28 | 5.10 | 4.70 | 4.28 | 3.82 | 3.33 | 2.80 | ||||
70 | Qo | 13580 | 12330 | 11170 | 10080 | 8140 | 6460 | 5020 | 3800 | 2770 | |||
Pe | 6.27 | 6.06 | 5.84 | 5.61 | 5.13 | 4.63 | 4.09 | 3.51 | 2.90 | ||||
RFC4D-6.2 | 30 | Qo | 29550 | 26900 | 24450 | 22200 | 18170 | 14720 | 11770 | 9270 | 7170 | 5410 | 3950 |
Pe | 4.35 | 4.28 | 4.20 | 4.10 | 3.89 | 3.64 | 3.35 | 3.04 | 2.70 | 2.33 | 1.95 | ||
40 | Qo | 26000 | 23650 | 21500 | 19490 | 15910 | 12830 | 10210 | 7980 | 6100 | 4520 | 3210 | |
Pe | 5.25 | 5.13 | 5.00 | 4.85 | 4.54 | 4.18 | 3.80 | 3.38 | 2.94 | 2.48 | 2.00 | ||
50 | Qo | 22550 | 20500 | 18630 | 16880 | 13740 | 11040 | 8730 | 6760 | 5100 | 3700 | 2540 | |
Pe | 6.08 | 5.90 | 5.72 | 5.53 | 5.11 | 4.66 | 4.17 | 3.66 | 3.13 | 2.57 | 1.99 | ||
RFC4G-9.2 | 50 | Qo | 22550 | 20550 | 18640 | 16890 | 13750 | 11040 | 8730 | 6770 | 5100 | ||
Pe | 6.07 | 5.90 | 5.72 | 5.53 | 5.12 | 4.66 | 4.18 | 3.66 | 3.12 | ||||
60 | Qo | 19250 | 17500 | 15870 | 14360 | 11650 | 9320 | 7320 | 5620 | 4180 | |||
Pe | 6.86 | 6.63 | 6.39 | 6.14 | 5.62 | 5.07 | 4.49 | 3.89 | 3.25 | ||||
70 | Qo | 15970 | 14520 | 13160 | 11900 | 9620 | 7660 | 5980 | 4560 | 3350 | |||
Pe | 7.57 | 7.29 | 6.99 | 6.69 | 6.07 | 5.43 | 4.76 | 4.06 | 3.34 | ||||
RFC4D-8.2 | 30 | Qo | 38400 | 35000 | 31800 | 28900 | 23600 | 19120 | 15280 | 12030 | 9280 | 6980 | 5080 |
Pe | 5.05 | 5.12 | 5.16 | 5.16 | 5.05 | 4.83 | 4.53 | 4.15 | 3.73 | 3.28 | 2.84 | ||
40 | Qo | 33950 | 30900 | 28050 | 25400 | 20700 | 16670 | 13220 | 10290 | 7810 | 5730 | 3990 | |
Pe | 6.63 | 6.52 | 6.39 | 6.24 | 5.87 | 5.43 | 4.93 | 4.40 | 3.83 | 3.26 | 2.69 | ||
50 | Qo | 29350 | 26700 | 24200 | 21900 | 17730 | 14170 | 11110 | 8520 | 6320 | 4470 | 2930 | |
Pe | 7.88 | 7.64 | 7.38 | 7.10 | 6.52 | 5.89 | 5.23 | 4.54 | 3.84 | 3.14 | 2.44 | ||
RFC4G-12.2 | 50 | Qo | 29100 | 26400 | 23900 | 21550 | 17390 | 13810 | 10750 | 8140 | 5940 | ||
Pe | 7.51 | 7.33 | 7.12 | 6.88 | 6.34 | 5.73 | 5.06 | 4.37 | 3.66 | ||||
60 | Qo | 24450 | 22150 | 19990 | 18000 | 14420 | 11340 | 8710 | 6460 | 4560 | |||
Pe | 8.49 | 8.18 | 7.86 | 7.51 | 6.79 | 6.02 | 5.21 | 4.40 | 3.58 | ||||
70 | Qo | 19850 | 17950 | 16170 | 14520 | 11540 | 8970 | 6760 | 4880 | 3290 | |||
Pe | 9.15 | 8.75 | 8.33 | 7.91 | 7.04 | 6.14 | 5.24 | 4.33 | 3.43 | ||||
RFC4D-10.2 | 30 | Qo | 44850 | 40850 | 37150 | 33700 | 27550 | 22300 | 17790 | 13960 | 10730 | 8020 | 5760 |
Pe | 5.88 | 6.01 | 6.08 | 6.10 | 5.99 | 5.73 | 5.33 | 4.84 | 4.30 | 3.73 | 3.17 | ||
40 | Qo | 39600 | 36000 | 32700 | 29650 | 24150 | 19410 | 15360 | 11920 | 9000 | 6540 | 4480 | |
Pe | 7.63 | 7.56 | 7.45 | 7.29 | 6.89 | 6.38 | 5.77 | 5.11 | 4.41 | 3.70 | 3.01 | ||
50 | Qo | 34200 | 31100 | 28200 | 25450 | 20600 | 16450 | 12870 | 9820 | 7230 | 5050 | 3220 | |
Pe | 9.11 | 8.85 | 8.56 | 8.26 | 7.58 | 6.84 | 6.05 | 5.24 | 4.40 | 3.58 | 2.77 | ||
RFC4G-15.2 | 50 | Qo | 34700 | 31450 | 28450 | 25650 | 20650 | 16350 | 12680 | 9560 | 6930 | ||
Pe | 8.78 | 8.54 | 8.28 | 8.00 | 7.36 | 6.65 | 5.88 | 5.07 | 4.24 | ||||
60 | Qo | 29250 | 26500 | 23900 | 21500 | 17170 | 13450 | 10270 | 7550 | 5260 | |||
Pe | 9.80 | 9.44 | 9.06 | 8.67 | 7.83 | 6.94 | 6.01 | 5.05 | 4.07 | ||||
70 | Qo | 23850 | 21550 | 19380 | 17380 | 13770 | 10650 | 7960 | 5670 | 3720 | |||
Pe | 10.58 | 10.12 | 9.64 | 9.15 | 8.14 | 7.09 | 6.00 | 4.89 | 3.76 | ||||
RFC4D-12.2 | 30 | Qo | 50900 | 46300 | 42100 | 38250 | 31300 | 25350 | 20250 | 15930 | 12290 | 9240 | 6700 |
Pe | 7.45 | 7.40 | 7.33 | 7.22 | 6.93 | 6.55 | 6.10 | 5.58 | 5.01 | 4.41 | 3.79 | ||
40 | Qo | 45300 | 41200 | 37450 | 33950 | 27700 | 22300 | 17680 | 13760 | 10440 | 7650 | 5320 | |
Pe | 9.16 | 8.97 | 8.75 | 8.50 | 7.95 | 7.33 | 6.65 | 5.92 | 5.17 | 4.39 | 3.61 | ||
50 | Qo | 39550 | 35950 | 32600 | 29500 | 23900 | 19090 | 14980 | 11480 | 8510 | 6020 | 3930 | |
Pe | 10.79 | 10.45 | 10.09 | 9.71 | 8.88 | 7.99 | 7.05 | 6.10 | 5.15 | 4.22 | 3.34 | ||
RFC4G-20.2 | 50 | Qo | 40250 | 36500 | 33000 | 29800 | 23950 | 18970 | 14690 | 11040 | 7940 | ||
Pe | 10.42 | 10.11 | 9.77 | 9.41 | 8.63 | 7.77 | 6.85 | 5.88 | 4.89 | ||||
60 | Qo | 33900 | 30650 | 27650 | 24850 | 19850 | 15530 | 11830 | 8690 | 6020 | |||
Pe | 11.65 | 11.20 | 10.72 | 10.22 | 9.18 | 8.10 | 6.98 | 5.84 | 4.70 | ||||
70 | Qo | 27500 | 24850 | 22350 | 20000 | 15840 | 12240 | 9150 | 6520 | 4300 | |||
Pe | 12.59 | 12.01 | 11.42 | 10.82 | 9.57 | 8.30 | 7.02 | 5.75 | 4.52 | ||||
RFC4D-15.2 | 30 | Qo | 69100 | 62800 | 57000 | 51600 | 49150 | 33700 | 26700 | 20850 | 15920 | 11840 | 8500 |
Pe | 10.40 | 10.07 | 9.74 | 9.41 | 8.74 | 8.07 | 7.38 | 6.67 | 5.95 | 5.20 | 4.42 | ||
40 | Qo | 61300 | 55700 | 50400 | 45600 | 37000 | 29600 | 23350 | 18100 | 13700 | 10060 | 7080 | |
Pe | 12.46 | 11.93 | 11.43 | 10.93 | 9.97 | 9.04 | 8.13 | 7.23 | 6.32 | 5.39 | 4.44 | ||
50 | Qo | 54100 | 49050 | 44400 | 40100 | 32400 | 25800 | 20250 | 15570 | 11660 | 8430 | 5800 | |
Pe | 14.24 | 13.54 | 12.87 | 12.22 | 10.99 | 9.81 | 8.69 | 7.59 | 6.51 | 5.43 | 4.34 | ||
RFC4G-25.2 | 50 | Qo | 54100 | 49050 | 44400 | 40100 | 32400 | 25800 | 20250 | 15570 | 11660 | ||
Pe | 13.77 | 13.13 | 12.52 | 11.92 | 10.78 | 9.68 | 8.62 | 7.58 | 6.55 | ||||
60 | Qo | 47100 | 42700 | 38600 | 34800 | 28000 | 22200 | 17320 | 13190 | 9760 | |||
Pe | 15.04 | 14.27 | 13.53 | 12.81 | 11.44 | 10.13 | 8.89 | 7.69 | 6.53 | ||||
70 | Qo | 40250 | 36450 | 32900 | 29600 | 23750 | 18740 | 14500 | 10940 | 7980 | |||
Pe | 16.09 | 15.21 | 14.36 | 13.53 | 11.96 | 10.48 | 9.07 | 7.74 | 6.45 | ||||
RFC4D-20.2 | 30 | Qo | 78500 | 71400 | 64800 | 58600 | 47700 | 38350 | 30450 | 23800 | 18190 | 13560 | 9770 |
Pe | 12.45 | 12.15 | 11.83 | 11.50 | 10.78 | 10.00 | 9.16 | 8.26 | 7.31 | 6.32 | 5.28 | ||
40 | Qo | 69700 | 63300 | 57400 | 51900 | 42100 | 33750 | 26650 | 20700 | 15700 | 11570 | 8190 | |
Pe | 14.65 | 14.14 | 13.62 | 13.09 | 12.03 | 10.95 | 9.85 | 8.73 | 7.59 | 6.44 | 5.28 | ||
50 | Qo | 61500 | 55800 | 50500 | 45650 | 36950 | 29500 | 23200 | 17870 | 13430 | 9760 | 6770 | |
Pe | 16.67 | 15.93 | 15.20 | 14.48 | 13.06 | 11.67 | 10.31 | 8.97 | 7.66 | 6.37 | 5.10 | ||
RFC4G-30.2 | 50 | Qo | 61500 | 55800 | 50500 | 45650 | 36950 | 29500 | 23200 | 17870 | 13430 | ||
Pe | 16.09 | 15.42 | 14.76 | 14.10 | 12.79 | 11.50 | 10.22 | 8.94 | 7.67 | ||||
60 | Qo | 53700 | 48650 | 44000 | 39700 | 32000 | 25450 | 19890 | 15210 | 11300 | |||
Pe | 17.65 | 16.80 | 15.96 | 15.14 | 13.54 | 11.99 | 10.49 | 9.03 | 7.60 | ||||
70 | Qo | 45900 | 41600 | 37600 | 33850 | 27200 | 21550 | 16720 | 12680 | 9320 | |||
Pe | 19.22 | 18.16 | 17.14 | 16.15 | 14.25 | 12.46 | 10.75 | 9.12 | 7.55 | ||||
Suction gas temperature 20℃,50Hz,without liquid subcooling. | |||||||||||||
Additional cooling or limited suction gas temperature. |
3.3 Processing Features
The compressors of Daming suit different working condition and refrigerants,and could maximally satisfy your requirements for the refrigerating system.
Developed technology,compact dimension ,Small volume and space .
High precision machining to ensure the compressor confirm with the standard ,CNC processing center ,Concentrically due to specific processing technology ,minimal dead space .
Steady operation,small vibration and low noise ,Excellent stability .
Refrigerant like R22 and R404 are adopted to protect the environment ,For mid & low temperature application .
Electrical motor protect device ,PTC sensor .
Wear resistant driver gear ,Chrome plated piston rings and aluminium pistons ,Hardened crank-shaft ,Low friction bearing set .
Efficient valve plate design,high refrigerating capacity and low energy consumption ,Efficient compression rate ,Valve reed made of imported impact resistant spring steel .
General spare parts,convenient for maintenance.
3.4 Application Limits (Suction gas temperature 20°C)
R404A•R507A
RFC4D-3.2—RFC4G-9.2
R404A•R507A
RFC4D-8.2—RFC6G-50.2
R134a
R407C
To —— Evaporating temperature(°C)
Toh —- Suction gas temperature(°C)
Toh —- Suction super heat(K)
Tc ——-Condensing temperature(°C)
Additional cooling
Additional cooling&limited suction gas temperature
Additional cooling&liquid injection cooling system
3.4 Compressor Dimensional drawing
3.5 Packaging & Shipment
- FOB Port: Ningbo Lead Time:15- 30 days
- Packaging Size: 49*44*15 cm Net weight: 62 kg +
- Units per Export Carton:1 Gross weight: 70 kg +
- Dimensions per Unit:193 × 94 × 87 Centimeters
- Weight per Unit:117 Kilograms
- Export Carton Weight: 117 Kilograms
- Export Carton Dimensions L/W/H:193 × 94 × 87 Centimeters
3.6 Payment & Delivery
- Payment Method: Advance TT, T/T, L/C.
- Delivery Details: within 30-50 days after receiving your full payment .
3.7 Primary Competitive Advantage
- Small Orders Accepted Brand-name Parts Country of Origin
- Distributorships Offered Electronic Link Experienced Staff
- Form A Green Product Cost-effective
- International Approvals Military Specifications Standard Packaging
- Good Price Product Features Product Performance
- Prompt Delivery Quality Approvals Reputation
- Provide Good Service Sample Available Customized
- We have over 30 years of professional experience as a manufacturer of semi-hermetic compressor , scroll compressor , screw compressor ,condensing unit .
- We make the compressor according your usage
- We have strong researching and developing team to meet your requirement.
- There are lot of raw material suppliers around our factory, our factory in Zhejiang
- We supply high quality compressor for many world companies
- Our factory got ISO 9001 and apply CE certificate, importantly we have factory which bigger workshop over 20000sq meters .
- Small trial orders can be accepted, sample is available .
- Our price is reasonable and keep top quality for every clients.
Product detail pictures:
Related Product Guide:
Shengzhou Mayor visited Daming
Refrigeration Units – Storage Options You May Not Know About
We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our management ideal for Well-designed Condensing Unit Comperssor - RFC Semi-Hermetic Reciprocating Compressor R22 R404A R134A R507A 6D-25.2-6DS-30.2 – Daming Refrigeration Technology, The product will supply to all over the world, such as: Malaysia, Kazakhstan, Armenia, Our products are exported worldwide. Our customers are always satisfied with our reliable quality, customer-oriented services and competitive prices. Our mission is "to continue to earn your loyalty by dedicating our efforts to the constant improvement of our items and services in order to ensure the satisfaction of our end-users, customers, employees, suppliers and the worldwide communities in which we cooperate".
By Candance from Rio de Janeiro - 2018.07.27 12:26
High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
By Adelaide from Brunei - 2018.12.05 13:53