So as to provide you with ease and enlarge our business, we even have inspectors in QC Crew and guarantee you our best company and solution for Manufactur standard Low Temperature Compressor Copeland D4dj-3000 Germany Made Copeland Compressor, For even more inquires remember to do not hesitate to get in touch with us. Thank you – Your support continuously inspires us.
So as to provide you with ease and enlarge our business, we even have inspectors in QC Crew and guarantee you our best company and solution for Copeland Compressor, Low Temperature Compressor, Low Temperature Compressor Copeland, Our specialist engineering team will generally be prepared to serve you for consultation and feedback. We are able to also supply you with free of charge samples to meet your requirements. Best efforts will likely be produced to supply you the best service and merchandise. When you are keen on our business and products and solutions, make sure you speak to us by sending us emails or call us quickly. In an effort to know our products and company extra, you may come to our factory to view it. We’ll generally welcome guests from all over the world to our business to create business relations with us. Make sure you feel cost-free to speak to us for small business and we believe we’ll share the best trading experience with all our merchants.
1. ZheJiang DaMing Refrigeration Technology Co., Ltd. Profile
- Business Type: We are Manufacturer/Factory/Plant
- Main Products: compressor ,compressor unit .(reciprocating compressor, scroll compressor, screw compressor)
- Number of Employees: 300+
- Year of Establishment: 1990s
- Management System Certification: ISO 9001
- Location: ZheJiang, China (Mainland)
2. Basic Information
- Series: 4VD-15.2-4VG-30.2 Explanation of model designation
- Compressor Body Material: Iron 4/6 ———————Cylinders
- Application : Refrigeration S ———————-Model
- Refrigeration gas: R22, R404A,R134A,R507A 15 ———————–Horse Power
- Input Voltage: 3Ф 380V-420V/50HZ;440V-480V/60HZ 1 ———————–Series Code
- Origin: Zhejiang, China D/G———————D for Low Temp;G for mid & High Temp
- Specification: CE, CCC,ISO9001
3. Application Limits ( Suction Gas Temperature 20°C)
R404A & R507A
R407C
R22
To —— Evaporating temperature(°C)
Toh —- Suction gas temperature(°C)
Toh —- Suction super heat(K)
Tc ——-Condensing temperature(°C)
Additional cooling
Additional cooling&limited suction gas temperature
Additional cooling&liquid injection cooling system
4.Product Details
4.1 Key Specifications/Special Features -Technical Data Sheet
Model | NominalPowerHP/KW | Displacementm³/h 50Hz | Number ofCylinders×Diameter×Stoke | Exhaust & Suction Valve mm/IN | Oil Volume(L) | Power V/φ/Hz | Electrical Parameter | Crankcase Heater(220V)W | Oil SupplyMethod | Weight(Including Oil)Kg | ||
DLExhaust Valve | SLSuction Valve | Max OperatingCurrent(A) | Starting/ LockedCurrent(A) | |||||||||
4VD-15.2 | 15/10.5 | 73.7 | 4×φ70×55 | φ28 | φ42 | 4 | 380-420YY/3/50 440-480YY/3/60 | 31 | 81/132 | 140 | Forced-lubrication | 183 |
4VG-25.2 | 25/18.5 | 73.7 | 4×φ70×55 | φ28 | φ54 | 4.5 | 45 | 116/193 | 140 | 203 | ||
4VD-20.2 | 20/15 | 84.6 | 4×φ75×55 | φ28 | φ54 | 4.5 | 37 | 97/158 | 140 | 192 | ||
4VG-30.2 | 30/22 | 84.6 | 4×φ75×55 | φ28 | φ54 | 4.5 | 53 | 135/220 | 140 | 206 |
4.2 Refrigerating Performance – Cooling Capacity with R22
Model | Condensing Temperature℃ | Cooling Capacity Qo(W) Power Consumption Pe(kW) | |||||||||||||
Evaporating Temperature ℃ | |||||||||||||||
12.5 | 10 | 7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | -35 | -40 | |||
4VD-15.2 | 30 | Qo | 52300 | 42700 | 34450 | 27350 | 21300 | 16400 | 12000 | 8310 | |||||
Pe | 12.73 | 11.93 | 11.01 | 9.98 | 8.82 | 8.25 | 7.13 | 5.98 | |||||||
40 | Qo | 46850 | 38100 | 30500 | 24050 | 18500 | 13840 | 9800 | 6440 | ||||||
Pe | 14.91 | 13.81 | 12.56 | 11.19 | 9.76 | 8.67 | 7.30 | 5.90 | |||||||
50 | Qo | 41700 | 33700 | 26800 | 20900 | 15800 | 11500 | 7920 | 4970 | ||||||
Pe | 17.11 | 15.67 | 14.13 | 12.47 | 10.85 | 9.21 | 7.53 | 5.79 | |||||||
4VG-25.2 | 30 | Qo | 99300 | 91200 | 83600 | 76500 | 63700 | 52600 | 42950 | 34650 | 27500 | 21400 | 16260 | ||
Pe | 13.89 | 13.74 | 13.56 | 13.34 | 12.84 | 12.22 | 11.48 | 10.63 | 9.67 | 8.59 | 7.41 | ||||
40 | Qo | 89700 | 82300 | 75400 | 68900 | 57300 | 47150 | 38350 | 30800 | 24250 | 18670 | 13940 | |||
Pe | 16.75 | 16.47 | 16.16 | 15.82 | 15.05 | 14.17 | 13.18 | 12.07 | 10.85 | 9.52 | 8.08 | ||||
50 | Qo | 80500 | 73800 | 67600 | 61700 | 51100 | 41950 | 33950 | 27050 | 21100 | 16030 | ||||
Pe | 19.56 | 19.16 | 18.74 | 18.27 | 17.25 | 16.10 | 14.83 | 13.44 | 11.94 | 10.33 | |||||
4VD-20.2 | 30 | Qo | 60000 | 48950 | 39500 | 31400 | 24500 | 18940 | 13920 | 9670 | |||||
Pe | 14.64 | 13.67 | 12.63 | 11.51 | 10.29 | 9.65 | 8.40 | 7.10 | |||||||
40 | Qo | 53700 | 43700 | 35100 | 27750 | 21500 | 16080 | 11430 | 7530 | ||||||
Pe | 17.39 | 16.04 | 14.60 | 13.07 | 11.42 | 10.35 | 8.75 | 7.14 | |||||||
50 | Qo | 47800 | 38750 | 30950 | 24200 | 18350 | 13390 | 9230 | 5790 | ||||||
Pe | 20.10 | 18.40 | 16.65 | 14.89 | 13.14 | 11.23 | 9.19 | 7.06 | |||||||
4VG-30.2 | 30 | Qo | 114200 | 104800 | 96000 | 87800 | 73100 | 60400 | 49300 | 39800 | 31650 | 24700 | 18840 | ||
Pe | 16.42 | 16.23 | 16.01 | 15.74 | 15.11 | 14.33 | 13.44 | 12.45 | 11.36 | 10.21 | 9.00 | ||||
40 | Qo | 103000 | 94500 | 86500 | 79100 | 65700 | 54000 | 44000 | 35350 | 27950 | 21650 | 16330 | |||
Pe | 19.78 | 19.46 | 19.09 | 18.68 | 17.74 | 16.67 | 15.49 | 14.20 | 12.83 | 11.40 | 9.92 | ||||
50 | Qo | 92300 | 84600 | 77400 | 70700 | 58600 | 48100 | 39000 | 31200 | 24500 | 18810 | ||||
Pe | 23.40 | 22.90 | 22.30 | 21.70 | 20.40 | 19.04 | 17.57 | 16.05 | 11.49 | 12.91 | |||||
Based on 20℃ suction gas temperature,50Hz,without liquid subcooling. | |||||||||||||||
VARICOOL system,additional cooling,position of suction valve changed. | |||||||||||||||
Additional cooling or limited suction gas temperature. | |||||||||||||||
Additional cooling and CIC system. |
Refrigerating Performance - Cooling Capacity with R404A,R507A
Model | Condensing Temperature℃ | Cooling Capacity Qo(W) Power Consumption Pe(kW) | ||||||||||||
Evaporating Temperature ℃ | ||||||||||||||
7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | -35 | -40 | -45 | |||
4VD-15.2 | 30 | Qo | 58500 | 48400 | 39700 | 32200 | 25750 | 20250 | 15560 | 11630 | 8350 | |||
Pe | 15.78 | 14.84 | 13.79 | 12.63 | 11.40 | 10.10 | 8.77 | 7.43 | 6.10 | |||||
40 | Qo | 49850 | 41150 | 33600 | 27100 | 21500 | 16730 | 12660 | 9240 | 6380 | ||||
Pe | 18.16 | 16.80 | 15.34 | 13.82 | 12.25 | 10.65 | 9.05 | 7.47 | 5.93 | |||||
50 | Qo | 33950 | 27600 | 22050 | 17330 | 13270 | 9820 | 6920 | ||||||
Pe | 18.50 | 16.67 | 14.80 | 12.91 | 11.03 | 9.17 | 7.37 | |||||||
4VG-25.2 | 30 | Qo | 90700 | 83200 | 69700 | 57900 | 47750 | 38950 | 31350 | 24800 | 19210 | 14460 | 10460 | |
Pe | 16.14 | 16.07 | 15.72 | 15.14 | 14.36 | 13.41 | 12.32 | 11.11 | 9.81 | 8.46 | 7.08 | |||
40 | Qo | 77400 | 71000 | 59500 | 49400 | 40650 | 33000 | 26450 | 20800 | 15930 | 11800 | 8320 | ||
Pe | 19.56 | 19.22 | 18.37 | 17.32 | 16.11 | 14.76 | 13.31 | 11.78 | 10.20 | 8.60 | 7.00 | |||
50 | Qo | 64500 | 59100 | 49500 | 41000 | 33600 | 27200 | 21600 | 16830 | 12740 | 9260 | 6340 | ||
Pe | 22.78 | 22.18 | 20.84 | 19.33 | 17.71 | 15.98 | 14.18 | 12.34 | 10.49 | 8.65 | 6.86 | |||
4VD-20.2 | 30 | Qo | 67100 | 55500 | 45400 | 36750 | 29350 | 23000 | 17600 | 13060 | 9260 | |||
Pe | 18.22 | 17.12 | 15.89 | 14.55 | 13.12 | 11.62 | 10.08 | 8.53 | 6.97 | |||||
40 | Qo | 57200 | 47300 | 38700 | 31200 | 24800 | 19250 | 14540 | 10540 | 7160 | ||||
Pe | 20.94 | 19.36 | 17.68 | 15.93 | 14.13 | 12.30 | 10.47 | 8.65 | 6.89 | |||||
50 | Qo | 38750 | 31650 | 25450 | 20100 | 15480 | 11510 | 8120 | ||||||
Pe | 21.25 | 19.15 | 17.02 | 14.87 | 12.73 | 10.63 | 8.60 | |||||||
4VG-30.2 | 30 | Qo | 103800 | 95300 | 79900 | 66500 | 54900 | 44900 | 36250 | 28800 | 22450 | 17040 | 12480 | |
Pe | 19.21 | 19.07 | 18.57 | 17.81 | 16.84 | 15.70 | 14.41 | 13.02 | 11.57 | 10.09 | 8.61 | |||
40 | Qo | 89100 | 81800 | 68600 | 57000 | 47000 | 38250 | 30700 | 24200 | 18610 | 13860 | 9850 | ||
Pe | 23.37 | 22.88 | 21.73 | 20.38 | 18.88 | 17.26 | 15.56 | 13.81 | 12.06 | 10.33 | 8.68 | |||
50 | Qo | 74300 | 68200 | 57100 | 47400 | 38900 | 31500 | 25100 | 19580 | 14840 | 10810 | 7410 | ||
Pe | 27.01 | 26.20 | 24.46 | 22.58 | 20.60 | 18.56 | 16.50 | 14.45 | 12.45 | 10.54 | 8.76 | |||
Based on 20℃ suction gas temperature,50Hz,without liquid subcooling. | ||||||||||||||
Additional cooling or limited suction gas temperature. | ||||||||||||||
Additional cooling and CIC system. |
Refrigerating Performance - Cooling Capacity with r134a
Model | Condensing Temperature℃ | Cooling Capacity Qo(W) Power Consumption Pe(kW) | |||||||||||
Evaporating Temperature ℃ | |||||||||||||
12.5 | 10 | 7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | |||
4VD-15.2 | 30 | Qo | 69100 | 62800 | 57000 | 51600 | 49150 | 33700 | 26700 | 20850 | 15920 | 11840 | 8500 |
Pe | 10.40 | 10.07 | 9.74 | 9.41 | 8.74 | 8.07 | 7.38 | 6.67 | 5.95 | 5.20 | 4.42 | ||
40 | Qo | 61300 | 55700 | 50400 | 45600 | 37000 | 29600 | 23350 | 18100 | 13700 | 10060 | 7080 | |
Pe | 12.46 | 11.93 | 11.43 | 10.93 | 9.97 | 9.04 | 8.13 | 7.23 | 6.32 | 5.39 | 4.44 | ||
50 | Qo | 54100 | 49050 | 44400 | 40100 | 32400 | 25800 | 20250 | 15570 | 11660 | 8430 | 5800 | |
Pe | 14.24 | 13.54 | 12.87 | 12.22 | 10.99 | 9.81 | 8.69 | 7.59 | 6.51 | 5.43 | 4.34 | ||
4VG-25.2 | 50 | Qo | 54100 | 49050 | 44400 | 40100 | 32400 | 25800 | 20250 | 15570 | 11660 | ||
Pe | 13.77 | 13.13 | 12.52 | 11.92 | 10.78 | 9.68 | 8.62 | 7.58 | 6.55 | ||||
60 | Qo | 47100 | 42700 | 38600 | 34800 | 28000 | 22200 | 17320 | 13190 | 9760 | |||
Pe | 15.04 | 14.27 | 13.53 | 12.81 | 11.44 | 10.13 | 8.89 | 7.69 | 6.53 | ||||
70 | Qo | 40250 | 36450 | 32900 | 29600 | 23750 | 18740 | 14500 | 10940 | 7980 | |||
Pe | 16.09 | 15.21 | 14.36 | 13.53 | 11.96 | 10.48 | 9.07 | 7.74 | 6.45 | ||||
4VD-20.2 | 30 | Qo | 78500 | 71400 | 64800 | 58600 | 47700 | 38350 | 30450 | 23800 | 18190 | 13560 | 9770 |
Pe | 12.45 | 12.15 | 11.83 | 11.50 | 10.78 | 10.00 | 9.16 | 8.26 | 7.31 | 6.32 | 5.28 | ||
40 | Qo | 69700 | 63300 | 57400 | 51900 | 42100 | 33750 | 26650 | 20700 | 15700 | 11570 | 8190 | |
Pe | 14.65 | 14.14 | 13.62 | 13.09 | 12.03 | 10.95 | 9.85 | 8.73 | 7.59 | 6.44 | 5.28 | ||
50 | Qo | 61500 | 55800 | 50500 | 45650 | 36950 | 29500 | 23200 | 17870 | 13430 | 9760 | 6770 | |
Pe | 16.67 | 15.93 | 15.20 | 14.48 | 13.06 | 11.67 | 10.31 | 8.97 | 7.66 | 6.37 | 5.10 | ||
4VG-30.2 | 50 | Qo | 61500 | 55800 | 50500 | 45650 | 36950 | 29500 | 23200 | 17870 | 13430 | ||
Pe | 16.09 | 15.42 | 14.76 | 14.10 | 12.79 | 11.50 | 10.22 | 8.94 | 7.67 | ||||
60 | Qo | 53700 | 48650 | 44000 | 39700 | 32000 | 25450 | 19890 | 15210 | 11300 | |||
Pe | 17.65 | 16.80 | 15.96 | 15.14 | 13.54 | 11.99 | 10.49 | 9.03 | 7.60 | ||||
70 | Qo | 45900 | 41600 | 37600 | 33850 | 27200 | 21550 | 16720 | 12680 | 9320 | |||
Pe | 19.22 | 18.16 | 17.14 | 16.15 | 14.25 | 12.46 | 10.75 | 9.12 | 7.55 | ||||
Suction gas temperature 20℃,50Hz,without liquid subcooling. | |||||||||||||
Additional cooling or limited suction gas temperature. |
4.3 Processing Features
The compressors of Daming suit different working condition and refrigerants,and could maximally satisfy your requirements for the refrigerating system.
Developed technology,compact dimension ,Small volume and space .
High precision machining to ensure the compressor confirm with the standard ,CNC processing center ,Concentricity due to specific processing technology ,minimal dead space .
Steady operation,small vibracation and low noise ,Excellent stability .
Refrigerant like R22 and R404 are adopted to protect the environment ,For mid & low temperature application .
Electrical motor protect device ,PTC sensor .
Wear resistant driver gear ,Chrome plated piston rings and aluminium pistons ,Hardened crank-shaft ,Low friction bearing set .
Efficient valve plate design,high refrigerating capacity and low energy consumption ,Efficient compression rate ,Valve reed made of imported impact resistant spring steel .
General spare parts,convenient for maintenance.
4.4 Cross Reference (Application Limits )
Cross Reference |
||||
Item Description |
Daming Model |
Copeland Model |
Bitzer Model |
Displacement (KW) |
2 cylinders |
BFS31 |
C-0300 |
12.2 |
|
BFS41 |
C-0400 |
14.7 |
||
BFS51 |
C-0500 |
18.4 |
||
BFS81 |
C-0800 |
26.6 |
||
BFS101 |
C-1000 |
36 |
||
3 cylinders |
BFS151 |
C-1500 |
54 |
|
4 cylinders |
4S151D |
4SLW-1500 |
73.6 |
|
4S251G |
4SHH-2500 |
73.6 |
||
4S201D |
4STW-2000 |
84.5 |
||
4S301G |
4STH-3000 |
84.5 |
||
6 cylinders |
6S251D |
6SLW-2500 |
110.5 |
|
6S351G |
6SHH-3500 |
110.5 |
||
6S321D |
6STW-3200 |
126.8 |
||
6S401G |
6SJH-4000 |
126.8 |
||
6S401D |
6SUW-4000 |
151.6 |
||
6S501G |
6SKH-5000 |
151.6 |
||
Small size 2 cylinders |
2YD-2.2 |
2DC-2.2 |
13.5 |
|
2YG-3.2 |
2DC-3.2 |
13.5 |
||
2YD-3.2 |
2CC-3.2 |
16.2 |
||
2YG-4.2 |
2CC-4.2 |
16.2 |
||
Small size 4 cylinder ( hexagon shape) |
4YD-3.2 |
4FC-3.2 |
18.1 |
|
4YG-5.2 |
4FC-5.2 |
18.1 |
||
4YD-4.2 |
4EC-4.2 |
22.7 |
||
4YG-6.2 |
4EC-6.2 |
22.7 |
||
4YD-5.2 |
4DC-5.2 |
26.84 |
||
4YG-7.2 |
4DC-7.2 |
26.84 |
||
4YD-6.2 |
4CC-6.2 |
32.48 |
||
4YG-9.2 |
4CC-9.2 |
32.48 |
||
Medium size 4 cylinders (hexagon shape ) |
4YD-8.2 |
4TCS-8.2 |
41.33 |
|
4YG-12.2 |
4TCS-12.2 |
41.33 |
||
4YD-10.2 |
4PCS-10.2 |
48.5 |
||
4YG-15.2 |
4PCS-15.2 |
48.5 |
||
4YD-12.2 |
4NCS-12.2 |
56.25 |
||
4YG-20.2 |
4NCS-20.2 |
56.25 |
||
Large 4 cylinders |
4VD-15.2 |
4H-15.2 |
73.6 |
|
4VG-25.2 |
4H-25.2 |
73.6 |
||
4VD-20.2 |
4G-20.2 |
84.5 |
||
4VG-30.2 |
4G-30.2 |
84.5 |
||
Large 6 cylinders |
6WD-25.2 |
6H-25.2 |
110.5 |
|
6WG-35.2 |
6H-35.2 |
110.5 |
||
6WD-30.2 |
6G-30.2 |
126.8 |
||
6WG-40.2 |
6G-40.2 |
126.8 |
||
6WD-40.2 |
6F-40.2 |
151.6 |
||
6WG-50.2 |
6F-50.2 |
151.6 |
||
Double stage |
6WDS-20.2 |
S6H-20.2 |
110.5 |
|
6WDS-25.2 |
S6G-25.2 |
126.8 |
||
6WDS-30.2 |
S6F-30.2 |
151.6 |
4.5 Compressor Dimensional drawing
4.6 Packaging & Shipment
- FOB Port: Ningbo Lead Time:15- 30 days
- Packaging Size: 49*44*15 cm Net weight: 62 kg +
- Units per Export Carton:1 Gross weight: 70 kg +
- Dimensions per Unit:193 × 94 × 87 Centimeters
- Weight per Unit:117 Kilograms
- Export Carton Weight: 117 Kilograms
- Export Carton Dimensions L/W/H:193 × 94 × 87 Centimeters
5. Payment & Delivery
- Payment Method: Advance TT, T/T, L/C.
- Delivery Details: within 30-50 days after receiving your full payment .
3.7 Primary Competitive Advantage
- Small Orders Accepted Brand-name Parts Country of Origin
- Distributorships Offered Electronic Link Experienced Staff
- Form A Green Product Cost-effective
- International Approvals Military Specifications Standard Packaging
- Good Price Product Features Product Performance
- Prompt Delivery Quality Approvals Reputation
- Provide Good Service Sample Available Customized
- We have over 30 years of professional experience as a manufacturer of semi-hermetic compressor , scroll compressor , screw compressor ,condensing unit .
- We make the compressor according your usage
- We have strong researching and developing team to meet your requirement.
- There are lot of raw material suppliers around our factory, our factory in Zhejiang
- We supply high quality compressor for many world companies
- Our factory got ISO 9001 and apply CE certificate, importantly we have factory which bigger workshop over 20000sq meters .
- Small trial orders can be accepted, sample is available .
- Our price is reasonable and keep top quality for every clients.