Best refrigeration compressor manufacturer

Semi-Hermetic Reciprocating Compressor R22 R404A R134A R507A


  • MALITIA Price:Negotiable
  • Min.Order Quantitas:1 0Piece
  • Capacitas producens:(V) Pieces per mense
  • Portus:Ningbo
  • Pensio conditio:L/C,T/T
  • origo plantarum;Zhejiang, China
  • Compressor Corpus Material:Ferrum
  • Applicatio:Refrigeration
  • Refrigerant:R22, R134A, R404A,R507C, R407C
  • Potentia (V/Ф/Hz );380-420/3/50, 440-480/3/60 .
  • Certification:CE, CCC, ISO9001, etc
  • Crucem reference:BITZER, COPELAND, INVOTECH
  • Product Detail

    Product Tags

    1. ZheJiang DaMing Refrigeration Technology Co., Ltd.Profile

    • Negotium Type: Manufacturer sumus / Factory / Planta
    • Principalis Products: compressor -compressor unitas.reciproco compressor, compressor volumen compressor, cochlea)
    • Numerus Employees: 300+
    • Annus Instituti: 1990s
    • Management System Certification: ISO 9001
    • Locus: ZheJiang, Sina (continens)

     e31d75972

    2. Basic Information

    • Series: 2YD-2.2-2YG-4.2 Explicatio exemplaris designationis
    • Compressor Corpus Material: Ferrum 2/4/6 -------------- Cylindri
    • Applicationem: Refrigeratio Y/V/W -------------- Model
    • Refrigeratio gas: R22, R404A,R134A,R507A
    • Input intentione: 3Ф 380V-420V/50HZ; 440V-480V/60HZ
    • Origin: Zhejiang, Sina D / G -------------- D ad Minimum Temp, G ad medium & High Temp
    • Specification: CE, CCC, ISO9001 2 ---------- Virtutis equitum
    • 2 -------------- Series Code

     

    3. Application limites (Suctionis Gas Temperature XX ° C *

    R404A & R507A

    AplicationLimits1

    R134A

    AplicationLimits3

    R22 (Aeris refrigerationem)

    AplicationLimits5

    Suctionis gas refrigerationem

    AplicationLimits6

    Ad - temperatus evaporans (° C)
    Toh - SUCTUS gas temperatus (°C)
    Toh -- Suctionis super calor (K)
    Tc --- Condensing temperatus (° C)
    TULIAdditional refrigerationem

    Additional refrigerationem & limited suctu Gas temperatus

    Additional refrigerationem & liquidam iniectio refrigerationem systema

    4.Product Details

    4.1 Key Specifications / Praecipua Features -Technical Data Sheet

    Model Nominal PowerHP/KW Displacementm³/h 50Hz Numerus ofCylinders×

    Diameter×

    Stoke

    Exhauriunt & Suctionis Valvae mm/IN Oleum Volume(L) PowerV/φ/Hz Electrical Parameter CrankcaseHeater

    (220V)W

    Oleum SupplyMethod Pondus (Oleum Complectens)

    Kg

    DL ExhaustValve SL SuctionValve Max OperatingCurrent(A) Satus / LockedCurrent(A)
    2YD-2.2 2/1.5 13.4 2×Φ50×39.3 φ16 φ22 1.5 220-240△/380-420Y/3/50 265-290△/440-480Y/3/60 11.9/6.9 53.7/30.7 120 Centrifugallubrication 67.5
    2YG-3.2 3/2.2 13.4 2×Φ50×39.3 φ16 φ22 1.5 13.5/7.8 64/37 120 70.5
    2YD-3.2 3/2.2 16.2 2×Φ55×39.3 φ16 φ22 1.5 14.8/8.5 64/37 120 70
    2YG-4.2 4/3 16.2 2×Φ55×39.3 φ16 φ22 1.5 16.4/9.4 76.6/44.2 120 70

     

    4.2 Refrigerating euismod - Refrigerans Capacitas cum R22

    Model CondensingTemperature℃ Refrigerium capacitas Qo(W) Power Consummatio Pe (kW)
    Evaporatio Temperature
    12.5 10 7.5 5 0 -5 -10 -15 -20 -25 -30 -35 -40
    2YD-2.2 30 Qo 9110 7430 5980 5150 4030 3100 2330 1700
    Pe 2.42 2.39 2.14 2.02 1.82 1.62 1.43 1.24
    40 Qo 7970 6430 5110 4370 3370 2550 1870 1330
    Pe 2.77 2.57 2.35 2.22 1.97 1.73 1.49 1.26
    50 Qo 6790 5400 4200 3520 2660 1960 1390
    Pe 3.08 2.80 2.53 2.40 2.09 1.850 1.54
    2YG-3.2 30 Qo 17280 15860 14530 13290 11060 9120 7440 5990 4740 3670 2770
    Pe 2.01 2.14 2.24 2.31 2.36 2.33 2.24 2.09 1.92 1.74 1.58
    40 Qo 15400 14110 12910 11780 9750 7980 6450 5120 3970 3000 2160
    Pe 2.89 2.92 2.93 2.92 2.84 2.69 2.50 2.28 2.06 1.86 1.70
    50 Qo 13490 12320 11230 10220 8380 6780 5390 4190 3160 2270
    Pe 3.64 3.59 3.52 3.44 3.23 2.98 2.72 2.45 2.20 2.00
    2YD-3.2 30 Qo 11350 9290 7500 6390 5040 3890 2940 2160
    Pe 2.85 2.74 2.56 2.40 2.15 1.91 1.70 1.49
    40 Qo 9880 8010 6380 5400 4160 3140 2290 1600
    Pe 3.32 3.07 2.79 2.56 2.27 2.00 1.74 1.47
    50 Qo 8370 6680 5230 4450 3340 2430 1680
    Pe 3.73 3.39 3.04 2.79 2.46 2.19 1.90
    2YG-4.2 30 Qo 21400 19650 18020 16490 13750 11360 9290 7510 5970 4660 3550
    Pe 2.48 2.63 2.74 2.83 2.91 2.88 2.78 2.61 2.40 2.17 1.93
    40 Qo 18960 17380 15910 14540 12050 9890 8020 6390 5000 3800 2780
    Pe 3.67 3.69 3.68 3.64 3.51 3.31 3.06 2.79 2.51 2.24 2.01
    50 Qo 16490 15080 13760 12520 10290 8350 6670 5210 3960 2880
    Pe 4.61 4.51 4.40 4.27 3.99 3.67 3.33 3.01 2.72 2.47
    Ex 20℃ exsugendo gas temperiei, 50Hz, sine liquore subcooling.
    VARICOOL systema, refrigeratio addita, positio valvae suctionis mutata est.
    Additional refrigeratio vel limitata suctio gas temperie.
    Additamentum refrigerationis et ratio CIC.

    Refrigerating euismod - Capacitas refrigerandi cum R404A,R507A

    Model CondensingTemperature℃ Refrigerium capacitas Qo(W) Power Consummatio Pe (kW)
    Evaporatio Temperature
    7.5 5 0 -5 -10 -15 -20 -25 -30 -35 -40 -45
    2YD-2.2 30 Qo 10110 8340 6810 5490 4360 3390 2570 1880 1300
    Pe 2.72 2.59 2.43 2.25 2.05 1.83 1.59 1.35 1.09
    40 Qo 8490 68880 5670 4530 3560 2720 2020 1420 920
    Pe 3.15 2.94 2.7 2.44 2.17 1.88 1.58 1.28 0.98
    50 Qo 6900 5640 4550 3600 2780 2080 1490 990
    Pe 3.55 3.25 2.93 2.59 2.25 1.9 1.54 1.19
    2YG-3.2 30 Qo 15940 14630 12260 10200 8420 6870 5540 4400 3420 2590 1890
    Pe 2.79 2.8 2.77 2.71 2.6 2.45 2.28 2.08 1.86 1.62 1.37
    40 Qo 13510 12390 10380 8610 7080 5750 4600 3610 2760 2040 1430
    Pe 3.49 3.44 3.32 3.16 2.96 2.74 2.49 2.21 1.92 1.62 1.31
    50 Qo 11110 10180 8500 7030 5740 4630 3660 2820 2110 1510 1000
    Pe 4.11 4.02 3.8 3.55 3.27 2.96 2.63 2.29 1.93 1.57 1.2
    2YD-3.2 30 Qo 12470 10290 8400 6780 5380 4190 3180 2330 1630
    Pe 3.33 3.15 2.95 2.72 2.48 2.21 1.93 1.64 1.35
    40 Qo 10510 8650 7040 5640 4440 3420 2550 1810 1200
    Pe 3.85 3.58 3.29 2.98 2.65 2.32 1.97 1.62 1.27
    50 Qo 8590 7050 5710 4550 3540 2690 1950 1340
    Pe 4.35 3.98 3.60 3.21 2.80 2.39 1.98 1.57
    2YG-4.2 30 Qo 19440 17840 14960 12450 10280 8400 6770 5380 4190 3170 2320
    Pe 3.48 3.48 3.42 3.32 3.17 2.98 2.76 2.50 2.23 1.94 1.64
    40 Qo 16470 15110 12660 10520 8660 7050 5650 4450 3420 2540 1810
    Pe 4.31 4.25 4.08 3.86 3.61 3.33 3.02 2.69 2.34 1.98 1.61
    50 Qo 13550 12430 10400 8620 7070 5720 4550 3540 2690 1960 1340
    Pe 5.08 4.96 4.68 4.36 4.01 3.63 3.23 2.82 2.40 1.98 1.55
    Ex 20℃ exsugendo gas temperiei, 50Hz, sine liquore subcooling.
    Additional refrigeratio vel limitata suctio gas temperie.
    Additamentum refrigerationis et ratio CIC.

    Refrigerating euismod - Capacitas refrigerandi cum r134a

    Model CondensingTemperature℃ Refrigerium capacitas Qo(W) Power Consummatio Pe (kW)
    Evaporatio Temperature
    12.5 10 7.5 5 0 -5 -10 -15 -20 -25 -30
    2YD-2.2 30 Qo 11730 10680 9710 8810 7200 5820 4650 3660 2820 2120 1540
    Pe 1.82 1.79 1.75 1.71 1.63 1.53 1.43 1.31 1.18 1.03 0.87
    40 Qo 10320 9390 8530 7730 6300 5070 4030 3140 2390 1760 1240
    Pe 2.15 2.11 2.06 2.01 1.89 1.76 1.62 1.46 1.28 1.09 0.88
    50 Qo 8950 8150 7390 6690 5440 4360 3440 2660 1990 1430 970
    Pe 2.47 2.41 2.35 2.28 2.13 1.96 1.78 1.58 1.36 1.12 0.86
    2YG-3.2 50 Qo 8930 8120 7370 6670 5420 4350 3430 2650 1990
    Pe 2.41 2.35 2.29 2.22 2.07 1.91 1.74 1.54 1.33
    60 Qo 7670 6980 6320 5720 4630 3700 2890 2210 1630
    Pe 2.70 2.62 2.54 2.46 2.28 2.09 1.87 1.64 1.38
    70 Qo 6460 5860 5310 4800 3870 3070 2390 1810 1310
    Pe 3.00 2.90 2.80 2.70 2.49 2.25 2.00 1.71 1.41
    2YD-3.2 30 Qo 14820 13510 12290 11150 9130 7400 5920 4670 3610 2720 1980
    Pe 2.19 2.15 2.11 2.06 1.95 1.83 1.69 1.54 1.37 1.19 1.00
    40 Qo 13050 11880 10800 9790 8000 6450 5130 4010 3070 2270 1610
    Pe 2.62 2.56 2.50 2.43 2.27 2.11 1.92 1.72 1.50 1.27 1.03
    50 Qo 11340 10320 9370 8490 6910 5550 4390 3400 2570 1860 1280
    Pe 302 2.94 2.85 2.76 2.56 2.35 2.11 1.86 1.60 1.32 1.02
    2YG-4.2 50 Qo 11300 10280 9340 8460 6890 5540 4380 3400 2570
    Pe 3.03 2.95 2.86 2.76 2.56 2.34 2.10 1.85 1.58
    60 Qo 6960 8810 8000 7230 5870 4690 3680 2830 2100
    Pe 3.39 3.28 3.17 3.06 2.81 2.54 2.26 1.96 1.65
    70 Qo 8140 7390 6700 6050 4890 3890 3040 2310 1700
    Pe 3.75 3.61 3.48 3.34 3.04 2.73 2.40 2.06 1.70
    SUCTUS gas temperies 20℃,50Hz, sine liquore subcooling.
    Additional refrigeratio vel limitata suctio gas temperie.

    4.3 Processing Features

     mark4Compressores Daming diversis condicionibus laborantibus et refrigerantibus conveniunt, et maxime requisitis tuis ad refrigerandum systema satisfacere potuerunt.

     

    mark4

    technologia enucleata, dimensio compacta -Parvum volumen et spatium.

     

    mark4Magna praecisio machinatio ad confirmandum compressor per vexillum , CNC processus centrum , Concentricitas propter specifica technologiam processus , spatium minimum mortuum .

     

    mark4

    Stabilis operatio, parva tremor et humilis sonitus, Optima stabilitas.

     

    mark4

    Refrigerant sicut R22 et R404 adoptantur ad defendendum ambitum, propter applicationem medium & low temperies.

     

    mark4

    Electrical motricium custodiat fabrica, PTC sensorem.

     

    mark4

    Gere renitentes calces exactoris , Chrome piston anulos patella et aluminium pistons , crank-scapum obduratum , Minimum frictionem paro ferens .

     

    mark4Valvae bracteae efficientis design, alta refrigerandi capacitas et humilis industria consummatio, Compressio rate efficientis, Valvae calamus importatus impulsus resistens vere chalybe factus est.

     

    mark4

    Partes generales parce, ad victum commodae.

    4.4 Cross Reference (Application limites)

    Crucem reference

    Item

    Descriptio

    Daming

    Model

    Copeland

    Model

    Bitzer

    Model

    Displacement

    (KW)

    2 cylindrici

    BFS31

    C-0300

     

    12.2

    BFS41

    C-0400

     

    14.7

    BFS51

    C-0500

     

    18.4

    BFS81

    C-0800

     

    26.6

    BFS101

    C-1000

     

    36

     

    III cylindri

    BFS151

    C-MD

     

    54

     

    4 cylindrici

    4S151D

    4SLW-1500

     

    73.6

    4S251G

    4SHH-500

     

    73.6

    4S201D

    4STW-2000

     

    84.5

    4S301G

    4STH-3000

     

    84.5

     

    VI cylindri

    6S251D

    6SLW-250

     

    110.5

    6S351G

    6SHH-3500

     

    110.5

    6S321D

    6STW-3200

     

    126.8

    6S401G

    6SJH-4000

     

    126.8

    6S401D

    6SUW-4000

     

    151.6

    6S501G

    6SKH-5000

     

    151.6

     

    Parva magnitudo

    2 cylindrici

    2YD-2.2

     

    2DC-2.2

    13.5

    2YG-3.2

     

    2DC-3.2

    13.5

    2YD-3.2

     

    2CC-3.2

    16.2

    2YG-4.2

     

    2CC-4.2

    16.2

     

    Parva magnitudo

    4 cylindrici

    (Exagonum figura)

    4YD-3.2

     

    4FC-3.2

    18.1

    4YG-5.2

     

    4FC-5.2

    18.1

    4YD-4.2

     

    4EC-4.2

    22.7

    4YG-6.2

     

    4EC-6.2

    22.7

    4YD-5.2

     

    4DC-5.2

    26.84

    4YG-7.2

     

    4DC-7.2

    26.84

    4YD-6.2

     

    4CC-6.2

    32.48

    4YG-9.2

     

    4CC-9.2

    32.48

     

    Medius quantitas

    4 cylindrici

    (Exagonum figura)

    4YD-8.2

     

    4TCS-8.2

    41.33

    4YG-12.2

     

    4TCS-12.2

    41.33

    4YD-10.2

     

    4PCS-10.2

    48.5

    4YG-15.2

     

    4PCS-15.2

    48.5

    4YD-12.2

     

    4NCS-12.2

    56.25

    4YG-20.2

     

    4NCS-20.2

    56.25

     

    Magnae 4 cylindrici

    4VD-15.2

     

    4H-15.2

    73.6

    4VG-25.2

     

    4H-25.2

    73.6

    4VD-20.2

     

    4G-20.2

    84.5

    4VG-30.2

     

    4G-30.2

    84.5

     

    Magnae 6 cylindrici

    6WD-25.2

     

    6H-25.2

    110.5

    6WG-35.2

     

    6H-35.2

    110.5

    6WD-30.2

     

    6G-30.2

    126.8

    6WG-40.2

     

    6G-40.2

    126.8

    6WD-40.2

     

    6F-40.2

    151.6

    6WG-50.2

     

    6F-50.2

    151.6

     

    Duplex scaena

    6WDS-20.2

     

    S6H-20.2

    110.5

    6WDS-25.2

     

    S6G-25.2

    126.8

    6WDS-30.2

     

    S6F-30.2

    151.6

    4.5 Compressor Dimensional drawing

    drawing2y

     

     

     

     

    4.6 Packaging & Shipment

    • MALITIA Portus: Ningbo plumbum tempus: 15- 30 dies
    • Packaging Size: 49*44*15 cm Net pondus: 62 kg +
    • Unitates per Export Caxton:1 Gross pondus: 70 kg +
    • Dimensiones per Unit: 193 94 × 87 Centimeters
    • Pondus per Unit: CXVII chiliogrammata
    • Export Caxton pondus: 117 chiliogrammata
    • Export Caxton Dimensiones L/W/H:193 94 87 Centimeters

    Delivery-semi-hermetic1 delivery-semi-hermetic2DSC_4437

     

    5. Payment & Delivery

    Mark-Money Mark3 Mark1 Mark2

    • Solucionis methodo: Progredi TT, T/T, L/C.
    • Partus Details: intra 30-50 dies post plenam solutionem acceptam.

    Mark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-starMark-star

    3.7 Prima Competitiva Commodum

    • Parvus Ordines Brand-nomen Partibus patria Origin
    • Distributorships obtulit Electronic Link Experti Staff
    • Formam A Green Product cost-effective
    • International Approvals Specifications Military Standard Packaging
    • Good Price Product Features Product euismod
    • Promptus Delivery Qualitas Approvals fama
    • Providere bonum servitii Sample Available nativus
    • Plus XXX annos experientiae professionalis habemus ut fabricatorem compressoris semi-hermetici, librum compressorem, cochleae compressorem, unitatem densantem.
    • Compressor secundum usum tuum facimus
    • Fortem habemus investigationes et turmas elaborandas ut postulationi tuae occurram.
    • Multae materiae rudis praebitorum circa officinam nostram sunt, nostra officina in Zhejiang
    • Compressor pro multis societatibus mundi suppeditamus optimum
    • Nostra officina ISO 9001 obtinuit et libellum CE applicamus, potius officinas habemus quae maior officina super 20000sq metris.
    • Parvus ordo iudicii recipi potest, specimen est available.
    • Pretium nostrum rationabile est et quale summum pro omnibus clientibus servant.
    • Daming Damingcompressor

  • Previous:
  • Deinde:

  • Whatsapp Online Chat!